7 Technical Specifications
7 Technical Specifications
Electrical parameters
Supply voltage
+ 9 … 32 V
DC
Supply current
16 mA @ 24 V
Switching output
galvanic isolation
Peak peak voltage Vppsw: < 60 V
AC/DC
, max 1.25 A
potential difference < 120 V
DC
Mechanical parameters
Supply/Switch connection
Phoenix Contact:
MC1,5/4-G-3,5-1844236
Plug for connection:
FMC1,5/4-ST-3,5-1952283
CAN connection
9-pin D-Sub connector
Ambient conditions
Operation temperature:
0 °C ... 40 °C
Storage temperature:
-20 °C ... 70 °C
Atmospheric humidity:
20 % ... 85 %, non-condensing
Degree of protection of the housing
IP20 to EN 60529
Dimensions
77 mm x 45.8 mm x 18.2 mm
Weight
Approx. 50 g
CAN
Protocol
CAN 2.0 A and B according to ISO 11898-2
Supported baud rates
10k, 20k, 50k, 100k, 125k, 250k, 500k, 800k, 1 MBit/s
Additionally user-defined: 33.3, 62.5, 83.3, 200, 400 kBit/s
Automatic detection
Table 4: Technical data
8 Ordering Information
Product
Description
Article number
CANalarm
®
- Basic set
CANalarm
®
- Basic set
CANalarm
®
incl. short manual
PR-22565-00
Licenses for optional Software Modules
License „Failure Monitoring“
License key for failure monitoring of can nodes
SW-22565-10
License „Message Trigger“
License key for analyzing of CAN messages
SW-22565-11
Table 5: Ordering Information
Document: 22565-HB-1-4-E-CANalarm
15