Fault remedying
OptiMove CR07
Number
Description
Action
H13
Axis cannot be referenced, because already
referenced
H15
Parameter input in sequence program not
possible, because program is running
H16
Axis cannot be started
during reference
travel
Hardware
H20
24 VDC supply voltage too high (26.5 VDC)
Stop axis (soft stop)
H21
24 VDC supply voltage too low (20.8 VDC)
Emergency stop
Store axis position, current program number
and axis status
Stop the system
H23
EEPROM content invalid
Load factory configuration
DigitalBus
H30
Data validation error
Reject data
H31
Data outside the value range
Reject data
H32
Data reception overflow
Reject data
CAN bus
H40
Permanent CAN bus error (BUS_OFF), i.e. no
power supply or cable is not connected
H41
Too many errors during sending
(ERROR_PASSIVE)
H42
Overflow on data reception
H43
Overflow on transmission
H44
Master failed
Stop axis (soft stop)
H45
Data outside the value range
Reject data
H46
Invalid Node ID set
Node ID = 127