V
12/13
28
•
Operation
OptiMove CR07
The blinking LED of the key
indicates that reference point
travel has not been carried out yet.
2. Press
the key
The control unit starts the reference travel
3. At the end of the reference travel, the LED of the
key expires
and the axis is referenced
NOTE!
If the axis can collide somewhere, or the guns are incorrectly
mounted, or the lower reversing point is situated too low, the axis
can be stopped by pressing the
key. By pressing the key again,
the reference travel will continue.
The procedure described above relates to the reference point traveling in
manual operation. In the automatic operation mode, the reference point
traveling is triggered with ID no. 7 by the DigitalBus, and with the
corresponding command by the CAN bus.
Start/stop the axis
1. Switch on the axis control unit (see also "Switch on/off the axis
control unit")
2. If necessary, change to another program (see also "Program
change")
3. Press
the key.
The axis is started, and the selected program is activated. The
corresponding LED illuminates
4. Press
the key.
The axis is stopped
- The
display
A1
shows the actual axis position. The
corresponding LED remains unlit