Rev. 01 08/20
OptiFlex Pro BN
Safety
9
Electrical danger
The connecting cables between the control unit and the spray gun must
be installed in such a way, that they cannot be damaged during the
operation. Please observe the local safety regulations!
The plug connections between the powder spraying equipment and the
mains should only be removed when the power supply is switched off.
All maintenance activities must take place when the powder spraying
equipment is switched off.
The product may not be switched on until the booth is in operation. If the
booth stops, the product must switch off too.
Explosion hazard
The control units for the spray guns must be installed and used in zone
22. Spray guns are allowed in zone 21.
Only original Gema OEM parts are guaranteed to maintain the explosion
protection rating. If damages occur by using spare parts from other
manufacturers, the warranty or compensation claim is void!
Conditions leading to dangerous levels of dust concentration in the
powder spraying booths or in the powder spraying areas must be
avoided. There must be sufficient technical ventilation available, to
prevent a dust concentration of more than 50% of the lower explosion
limit (UEG = max. permissible powder/air concentration). If the UEG is
not known, then a value of 10 g/m³ should be considered (see EN
50177).
All unauthorized conversions and modifications to the electrostatic
spraying equipment are forbidden for safety reasons.
No safety devices should be dismantled or put out of operation.
Mandatory operational and workplace notices from the operating
company must be written in a comprehensible manner in the language
of equipment operators and posted in a suitable place.
Slip hazard
Powder lying on the floor around the powder spraying equipment is a
potentially dangerous source of slipping. Booths may be entered only in
the places suitable for it.
Static charges
Static charges can have the following consequences: Charges to people,
electric shocks, sparking. Proper grounding must be in place to prevent
objects from becoming charged.
Содержание OptiFlex Pro BN
Страница 12: ...Rev 01 08 20 12 Safety OptiFlex Pro BN ...
Страница 19: ...Rev 01 08 20 OptiFlex Pro BN Product description 19 Rating plate fig 4 ...
Страница 20: ...Rev 01 08 20 20 Product description OptiFlex Pro BN ...
Страница 24: ...Rev 01 08 20 24 Assembly Connection OptiFlex Pro BN ...
Страница 36: ...Rev 01 08 20 36 Operation OptiFlex Pro BN ...
Страница 44: ...Rev 01 08 20 44 Maintenance Repairs OptiFlex Pro BN ...
Страница 48: ...Rev 01 08 20 48 Disposal OptiFlex Pro BN ...
Страница 51: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 51 OptiFlex Pro BN Spare parts fig 11 ...
Страница 53: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 53 Stirrer hopper Spare parts fig 12 Stirrer hopper Spare parts ...
Страница 57: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 57 ...
Страница 58: ......
Страница 60: ...Rev 01 ...