Rev. 01 08/20
OptiFlex Pro BN
Operation
29
Description
Presetting
Powder output
60 %
(50% for device type CF)
Total air
4.0 Nm³/h
(2.5 Nm³/h for device type CF)
High voltage
80 kV
Spray current
20 µA
Electrode rinsing air
0.1 Nm³/h
Fluidizing air
1.0 Nm³/h (for device type F)
0.1 Nm³/h (for device type B and S)
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
As a factory default value, a powder rate of 50% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the
T3/T4
keys
– Adjust the total air volume according to the corresponding coating
requests
correct powder cloud
too little total air
Setting the powder output
1.
OR
Содержание OptiFlex Pro BN
Страница 12: ...Rev 01 08 20 12 Safety OptiFlex Pro BN ...
Страница 19: ...Rev 01 08 20 OptiFlex Pro BN Product description 19 Rating plate fig 4 ...
Страница 20: ...Rev 01 08 20 20 Product description OptiFlex Pro BN ...
Страница 24: ...Rev 01 08 20 24 Assembly Connection OptiFlex Pro BN ...
Страница 36: ...Rev 01 08 20 36 Operation OptiFlex Pro BN ...
Страница 44: ...Rev 01 08 20 44 Maintenance Repairs OptiFlex Pro BN ...
Страница 48: ...Rev 01 08 20 48 Disposal OptiFlex Pro BN ...
Страница 51: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 51 OptiFlex Pro BN Spare parts fig 11 ...
Страница 53: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 53 Stirrer hopper Spare parts fig 12 Stirrer hopper Spare parts ...
Страница 57: ...Rev 01 08 20 OptiFlex Pro BN Spare parts list 57 ...
Страница 58: ......
Страница 60: ...Rev 01 ...