V 03/13
28
•
Cleaning and maintenance
OptiFlex 2 V
Cleaning
WARNING:
If no dust mask or one of an insufficient filter class is worn when
cleaning the product, then the dust that is stirred up from the coat-
ing powder can cause respiratory problems.
- The ventilation system must be turned on for all cleaning work.
- A dust mask corresponding to filter class FFP2 or N95 at minimum
must be worn during any cleaning work.
Cleaning the fluidizing/suction unit
1. Remove the injector
2. Remove the fluidizing/suction unit
3. Clean the fluidizing/suction unit with compressed air. Also blow
off the suction tube with compressed air
4. Clean the injector (see therefore the injector user manual)
5. Reassemble the individual parts
Содержание OptiFlex 2 V
Страница 12: ......
Страница 18: ......
Страница 22: ......
Страница 26: ...V 03 13 24 Initial start up OptiFlex 2 V 11 12 13 14 15 16 17 18 19 20 21 ...
Страница 28: ......
Страница 32: ......
Страница 36: ...V 03 13 ...