Rev. 00 04/19
OptiCenter OC06
Start-up
55
No.
Parameters
Description
Value
3401
US sieve: 140 µm
Selection of ultrasonic sieve with mesh size
140 µm
0 / 1
3402
US sieve: 200 µm
Selection of ultrasonic sieve with mesh size
200 µm
0 / 1
3403
US sieve: 250-300 µm
Selection of ultrasonic sieve with mesh size
250 µm or 300 µm.
0 / 1
3404
US sieve: => 500 µm
Selection of ultrasonic sieve with mesh size
500 µm or larger (XXX-1180 µm)
0 / 1
3405
Fresh powder sieving
The recovery powder is sieved by default.
0 / 1
3406
Option Fresh powder system
Activates typical limits and default settings
for an external fresh powder system.
0 / 1
3410
Second OptiCenter B
OptiCenter is configured as the second
OptiCenter in a MultiColor MCS01 system.
0 / 1
3411
Option Trevisan / SAT
The OptiCenter control takes over the
default settings for a SAT vertical coating
system with a special closed cyclone.
0 / 1
3412
Option Operating mode Hand
guns
0 / 1
3413
Option Powder recovery
0 / 1
3413
Number of injectors 1-12
Selection Number of injectors
1-12
1-24
1-36
3440
Filling level OptiSpeeder
Setting the desired powder filling level in
the OptiSpeeder:
55-100%
3441
Filling level Hysteresis
Hysteresis of the powder level
5-10%
3442
Time until start of powder
recovery after color change
In coating mode with powder recovery
(spray), the recovery powder is first fed into
the after filter after a color change and then
into the OptiSpeeder after the set time has
elapsed in the case of increased quality
requirements after a color change.
0-600 s
3460
Fresh powder request delay
In coating mode with powder recovery
(spray), fresh powder is fed into the
OptiSpeeder after the set time has elapsed
in addition to the recovery powder feed until
the powder level set at parameter 3440 is
reached again.
0-180 s
3461
Monitoring the fresh powder
request
If in automatic mode the powder level set in
parameter 3440 is not reached after the set
time has elapsed, an error message is
triggered.
0.3-5.0
min
3462
Monitoring the level sensor
stop powder circuit
If in automatic mode the powder level set in
parameter 3440 is not reached after the set
time has elapsed, the powder feed of fresh
and recovery powder is stopped for safety
reasons (overfill protection) and an error
message is triggered.
3.0-10.0
min