Rev. 00 04/19
OptiCenter OC06
Product description
25
Fig. 15
Level sensor**
–
For level detection in the powder bag cone or in the powder hopper
–
Height adjustable
–
Fluidized in the measuring range
Fig. 16
Principle of function
Powder circuit
During the typical OptiCenter (
7
) operation, the powder bag is put in the
powder bag cone. The powder is fluidized in the bag with the
fluidizing/suction lance and then fed to the OptiSpeeder (
9
). The fluidized
powder is sucked in by the conveyors and fed through the powder hoses
to the guns/spray nozzles (
8
). The powder, which does not adhere to the
workpieces, will be absorbed by the exhaust air of the booth (
1
) and
separated from the air in the cyclone separator (
2
).
The separated powder is cleaned by passing it through the integrated
sieve (
3
) and fed back into the OptiSpeeder (
9
) by the dense phase
conveyor (
4
), where it is prepared again for coating operation.
Fig. 17: Powder flow in the plant