Coating operation
OptiCenter OC04
haust air edge of the powder container; otherwise too much powder
can be sucked to the waste.
6. Set the powder container fluidizing air
with the corresponding
pressure regulator
−
The powder fluidization depends on the powder type, the air hu-
midity and the ambient temperature.
−
The powder must lightly "boil"
WARNING:
If the fluidization has been incorrectly adjusted, then the coating
powder can create a dust cloud capable of causing respiratory prob-
lems.
►
Adjust the fluidization correctly
7. Set the powder container aeration with the hand lever
−
Turn the hand lever to the stop, so that the dust cloud is drawn
slightly backwards
−
The stop can be set on the OptiCenter rear side
8. Set the level sensor fluidizing air
with the corresponding pres-
sure regulator
−
The powder fluidization depends on the powder type, the air hu-
midity and the ambient temperature.
9. Turn on the recovery powder pump, if necessary
10. Select desired operating mode (
AUTOMATIC
or
MANUAL
) on the
booth control unit (see therefore the corresponding operating manu-
al)
11. Start the coating procedure