V
04/17
12
•
Product description
OptiCenter OC04
Cleaning
−
Automatic internal cleaning of the injectors, powder hoses and
guns
−
Supply of the recovered powder
−
The workplace and the environment remain clean
−
No own exhaust system - the powder management center does
not have its own exhaust system and will be therefore connected
directly to the After Filter
Reasonably foreseeable misuse
−
Use of moist powder
−
Insufficient fluidization at the suction point
−
Operation without the proper training
Technical Data
Powder transport
OptiCenter OC04
Conveying performance (average value per
gun)
200 g/min.
Recovery
max. 3.5 kg/min.
Electrical data
OptiCenter OC04
Connected load
1x230 V
Frequency 50/60
Hz
Protection type
IP54
Pneumatic data
OptiCenter OC04
Inlet pressure
min. 6.5 bar
Compressed air consumption during coating
operation
15 Nm³/h
Compressed air consumption during cleaning
(incl. powder container and guns)
350 Nm³/h
Compressed air consumption during cleaning
of the PP06 hose to the cyclone
120 Nm³/h
Water vapor content of compressed air
max. 1.3 g/m³
Oil content of compressed air
max. 0.1 mg/m³