V 10/17
MagicCompact BA04
Troubleshooting
•
39
Problem/error/malfunction
Procedures/remedy
Bad separation efficiency of the
cyclone
Check all gaskets, above all, on
the powder separation of the cy-
clone and if necessary, repair
them
Check the exhaust air volume
flow, if necessary, clear blocked
tubes or repair the After Filter
Check the cyclone casing for
holes, caused by wear
Check the pretension force of the
closings
Sieve clogged up
Check the powder for dampness
Check, if too much powder was
fed through the cyclone, e.g. dur-
ing the booth cleaning
Automatic floor blow-off system
not OK
Check the compressed air supply
Pressure reducing valve defec-
tive or adjusted incorrectly
Solenoid valve defective (coil,
cable) or missing signal
Setting values
NOTE:
The setting values for the OptiCenter and other plant units you will
find in the corresponding operating instructions!
Содержание MagicCompact BA04
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 24: ......
Страница 28: ......
Страница 32: ......
Страница 36: ......
Страница 42: ......
Страница 49: ...V 10 17 MagicCompact BA04 Spare parts list 47 Gun blow off equipment fig 11 Gun blow off equipment ...
Страница 53: ...V 10 17 MagicCompact BA04 Spare parts list 51 Fan control unit fig 13 Fan control unit ...