V 10/17
MagicCompact BA04
Maintenance
•
29
Functional check
General information
A function check is to be carried out:
–
after a replacement of spare parts on the booth or on the electrical
part of the booth, or on plant units connected to the booth
–
after manipulations on the electrical part, or on external plant units
connected to the booth control unit, or on the booth control unit itself
–
after long stops/standstills
Procedure of the function check
1.
Switch on the main switch, control units and all interlocked equip-
ment should not be able to be switched on
2.
Turn the key switch, the control unit is activated, the operating unit is
activated and the key switch returns to its starting position. Control
units and all interlocked equipment should not be able to be
switched on
3.
Start the system, the main menu appears on the operating unit
4.
The operation of the OptiCenter is described in the corresponding
user manual
5.
Switch on the gun control units, if necessary
6.
Activate the automatic function on the operating unit, the reciproca-
tors move to the reference point. All interlocked plant units are ena-
bled (ES control unit etc.)
7.
The control units and all interlocked plant units are ready for opera-
tion
8.
The message "too little powder" appears on the operating unit after a
delay, and the alarm horn sounds
Содержание MagicCompact BA04
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 24: ......
Страница 28: ......
Страница 32: ......
Страница 36: ......
Страница 42: ......
Страница 49: ...V 10 17 MagicCompact BA04 Spare parts list 47 Gun blow off equipment fig 11 Gun blow off equipment ...
Страница 53: ...V 10 17 MagicCompact BA04 Spare parts list 51 Fan control unit fig 13 Fan control unit ...