www.gemu-group.com
12 / 24
GEMÜ 225
8 Manufacturer's information
8 Manufacturer's information
8.1 Delivery
●
Check that all parts are present and check for any dam-
age immediately upon receipt.
The product's performance is tested at the factory. The
scope of delivery is apparent from the dispatch documents
and the design from the order number.
8.2 Transport
1. Only transport the product by suitable means. Do not
drop. Handle carefully.
2. After the installation dispose of transport packaging ma-
terial according to relevant local or national disposal reg-
ulations / environmental protection laws.
8.3 Storage
1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their
spare parts.
8.4 Scope of delivery
The following is included in the scope of delivery:
•
Solenoid valve with solenoid coil
•
Plug
•
Installation, operating and maintenance instructions
9 Installation in piping
WARNING
The equipment is subject to pressure!
▶
Risk of severe injury or death.
●
Depressurize the plant.
●
Completely drain the plant.
CAUTION
Hot plant components!
▶
Risk of burns.
●
Only work on plant that has cooled
down.
CAUTION
Operating pressure to high or working medium temperature
too high
▶
Damage to the valve body
●
Only install the solenoid valve in aligned pipes in order to
avoid stresses in the valve body.
●
Do not exceed the permissible operating pressure.
●
Do not exceed the permissible temperature of the work-
ing medium.
9.1 Installation with solvent cement sockets
CAUTION
Wrong solvent cement
▶
Valve body will be damaged.
●
Only use solvent cement suitable for the valve body.
NOTICE
▶
The solvent cement is not included in the scope of deliv-
ery.
●
Only use suitable solvent cement!
1. Apply solvent cement inside the valve body socket con-
nections and on the piping as specified by the solvent ce-
ment manufacturer.
2. Solvent cement the valve body to the piping.
9.2 Installation with solvent cement spigots
CAUTION
Wrong solvent cement
▶
Valve body will be damaged.
●
Only use solvent cement suitable for the valve body.
NOTICE
▶
The solvent cement is not included in the scope of deliv-
ery.
●
Only use suitable solvent cement!
1
2
1
2
1. Apply solvent cement on the outside of the valve body
spigots
1
and on the inside of the piping connector
2
as
specified by the solvent cement manufacturer.
2. Connect the valve body to the piping.
9.3 Installation with threaded sockets
NOTICE
Thread sealant
▶
The thread sealant is not included in the scope of deliv-
ery.
●
Only use appropriate thread sealant.
●
Screw the threaded connections into the piping in accord-
ance with valid standards.
9.4 Installation with union ends
CAUTION
Do not use the solenoid coil as a lever
▶
If the solenoid coil is used as a lever, the solenoid coil
and bush could be destroyed.
●
Use only the spanner flats provided to screw the solen-
oid valve to the piping.
Содержание 225 DN 10
Страница 21: ...www gemu group com 21 24 GEM 225...
Страница 22: ...www gemu group com 22 24 GEM 225...