AIR HEATER PELLET STOVE BY GEKASMETAL
Page 17
- Within a menu, it selects and opens the specific menu.
- During the processing of a value, it records the value.
Prolonged press:
-In case the fuel storage is completely empty, it will empty the combustion chamber, resulting in the appearance of an error message, if the user attempts to refill it with the
pressing of the ON/OFF(ESK) button . Prolonged press of the ENTER button when the system is in <SHUTDOWN> phase or <INERTIA> phase, enables the fast activation of
inspection operation of supplier speed screen, and it will supply the combustion chamber with fuels (pellets) operating for 1 minute and 45 seconds without combustion.
6. Screen
The screen where all the information and menus of the boiler appear. The screen can be disabled after a regulated time. If disabled it returns with the pressing of any button.
In this case the normal function of the button is ignored.
7. Operation indicator
Switches on when boiler is operating. That is when start up is executed or there is fire in the combustion chamber.
8. Consumption indicator
Switches on when a selected fan is enabled.
9. Thermostat indicator
Switches on when an external thermostat is enabled.
10. Alert indicator
Does not concern this specific appliance!
11. Error indicator
Switches on when there is an error.
Activation
–
Deactivation
The control system, as long as it runs, is always at an operating phase. In order for the appliance to function and the control system to be at an operating phase it should,
firstly, be activated. The control system is considered activated when it is at any phase, except for the phase
<SHUTDOWN>
. If it is deactivated, the indication on the screen is
”
SHUTDOWN
”
. If it is activated the indication on the screen is the particular phase which is being executed that moment .The control system can be activated and deactivated
in many ways depending on actions of the user, the formulation of the system or an error. Specifically,
If it is disabled, it is enabled with:
<ON/OFF(ESC)> button single press
.
Then the control system moves to
<INERTIA>
phase
.
In case the start up is disabled, then the control system bypasses inertia and moves directly to start up
–
operation (
Initial cleaning-pre-heating-etc).
If it is enabled, it is disabled with:
<ON/OFF(ESC)> button prolonged press.
In this case the control system moves to
<SHUTDOWN>
phase, only if there are no fuels in the combustion chamber. If there are, then it returns to
<SHUTDOWN>
phase,
after executing full start up and shutdown, without holding. When this happens on the screen appears the indication
“
SWITCH OFF
”
for 5 sec.
To disable control system hold
down the <ON/OFF(ESC)> button for a SECOND time
.
Errors, like sensors errors. After detection/ restoration of such errors, the control system moves to
<SHUTDOWN>
phase
.
During switching off, it is disabled with:
<ON/OFF(ESC)>
prolonged press.
The control system state is being preserved during power cut. That means if the control system is enabled a power cut occurrs, when the system resumes and there is no fire
in the combustion chamber, the controller will move to
<INERTIA>
phase instead of
<SHUTDOWN>
.
All errors do not lead to
<SHUTDOWN>
phase
.
(
Consult errors
).
START UP AND OPERATION PHASES