The flues should have, across their length, diameter no less than that of the connection of the extraction pipe of the appliance. Possible changes are allowed only
on the entrance of the stove
They should be placed in a way that the formation of concentrate is controlled and the leakage from the connections is
They should be placed in distance from combustible materials no less than the one mentioned in the description of the product
The flue/pipe should allow the retrieval of soot, it should be cleaned and be inspected after being dismantled or through the inspection openings if it is not
accessible from the inside of the appliance
ADDITIONAL REQUIREMENTS FOR APPLIANCES EQUIPPED WITH ELECTRIC FAN FOR FUME DISCHARGE
For appliances which produce heat with electric fans for fume discharge, the instructions below should be followed:
The horizontal sections should have a slight inclination of 3% upwards
The length of the horizontal section should be minimum and in no case more than 3m
The number of the direction changes, including the use of a tee pipe, should not exceed 4.
EXAMPLES OF CORRECT CONNECTION
EXAMPLES OF CORRECT CONNECTION