background image

                                                                                                                                          

                                                                                                                       

 

AIR HEATER PELLET STOVE BY GEKASMETAL 

                                                                                  

 

Page 1

 

 

                      

 

 

 

 

 

 

      AMANDA 

9KW 

 

 

 

 

 

 

 

 

 

 

Manual 

 

 

 

 

 

 
 
 

Содержание AMANDA

Страница 1: ...AIR HEATER PELLET STOVE BY GEKASMETAL Page 1 AMANDA 9KW Manual...

Страница 2: ...METAL The pellet stove is an ideal heating solution It uses advanced technology and it has been constructed according the highest standards with modern design that allows you to enjoy your heat with...

Страница 3: ...r operator of the appliance should read and fully comprehend the content of this manual before attempting any use of it Mistakes or incorrect adjustments may cause dangerous conditions or and poor fun...

Страница 4: ...ext ignition Do not clean the product with water Water could leak into the appliance and destroy the electric insulation causing electrocution Do not stand in front of the appliance for a long time Av...

Страница 5: ...th the appliance The term guarantee refers to the free of charge replacement or repair of the parts of the appliance which are admitted as defective by construction RESTRICTIONS The above mentioned gu...

Страница 6: ...the European market and guarantee that the following characteristics are being retained Thermal value 4 9 kWh kg Humidity max 10 of its weight Ash percentage max 0 5 of its weight Diameter 5 6 mm Len...

Страница 7: ...here should be an ventilation opening The air pipes should comply with following requirements Be protected with racks metal nets etc without reducing however the useful part Be constructed in such way...

Страница 8: ...ggested CONNECTION TO ELECTRIC NETWORK Before the connection of the appliance to electric network check if the electrical installation is equipped with ground and differential switch according to regu...

Страница 9: ...cross flammable materials the above instructions should be followed SYMBOL DESCRIPTION HEIGHT mm b Minimum distance from combustible materials from the inside of the ceiling floor wall 500 B Minimum d...

Страница 10: ...pe should allow the retrieval of soot it should be cleaned and be inspected after being dismantled or through the inspection openings if it is not accessible from the inside of the appliance ADDITIONA...

Страница 11: ...ns only with negative pressure in relation to the environment and should be according to EN 14785 2006 Flue terminals The flue terminals should comply with the following requirements They should be se...

Страница 12: ...N 14785 2006 In case of pellet appliances the fume extraction systems should have leak tightness if they use elements of double definition G and O with or without elastomeric sealing For the connectio...

Страница 13: ...to remove it The glass should be cleaned using a dry cloth If needed you can use water and a soft detergent only if the glass is cold Once in a month clean the area behind the ash tank by removing th...

Страница 14: ...that performed the actions of inspection or and maintenance along with contact information date and signature of the technician 5 TECHNICAL CHARACTERISTICS MODEL WOOD PELLET STOVE AMANDA DIMENSIONS Hx...

Страница 15: ...causes exit without recording the value During the processing of text it causes exit without recording the text Prolonged press Switches off the boiler performing all necessary actions ignition combu...

Страница 16: ...th Minus button it changes the current indications screen Main Screen Entries Screen Exits Screen 4 Minus Button Decrease and navigation button Single press Enables the screen for room temperature set...

Страница 17: ...it should firstly be activated The control system is considered activated when it is at any phase except for the phase SHUTDOWN If it is deactivated the indication on the screen is SHUTDOWN If it is a...

Страница 18: ...re then the controller moves to the INERTIA phase or the SHUTDOWN phase depending on whether it was enabled or disabled before the interruption of electrical supply voltage During the first ignition i...

Страница 19: ...nd the combustion fans are adjusted automatically in order to achieve the desirable operation temperature Manually When a manual program has been selected then the control system is not enabled On the...

Страница 20: ...he control system in this phase and for a small period of time preserve their former speed After this period of time and for the rest of the phase the combustion fan functions with maximum speed The s...

Страница 21: ...The entry signals remain activated The system does not return in function if the error has not been removed by the user 22 Low Fumes Fume temperature below the limit for a specific period of time The...