5.  Safety instructions for assembly

 

I

ATTENTION: Important safety instructions. Follow all installation 

instructions, as incorrect installation can lead to serious injuries.

 

f

When mounting the motor without any mechanical protection of the driven parts and 

of the tube which may become hot, the motor must be installed at a height of at least 

2.5 m above the ground or of another level which provides access to the drive.

 

f

Before the motor is installed, all cables which are not needed are to be removed and 

all equipment which is not needed for power-operated actuation is to be put out of 

operation.

 

f

The actuating element of a manual release must be mounted at a height of less than 

1.8 m.

 

f

If the motor is controlled by a switch or pushbutton, the switch or pushbutton must 

be mounted within eyeshot of the motor. The switch or pushbutton must not be 

located in the vicinity of moving parts. The height of installation must be at least 

1.5 m above the floor.

 

f

Permanently installed control devices must be attached visibly.

 

f

In case of devices extending horizontally, a horizontal distance of at least 0.4 m must 

be respected between the fully extended part and any other fixed element.

 

f

The rated speed and the rated torque of the motor must be compatible with the 

device.

 

f

The mounting accessories that are used must be designed in accordance with the 

selected rated torque.

 

f

Good technical knowledge and good mechanical skills are necessary for the motor 

installation. Incorrect installation can lead to serious injury. 

Electrical work must be carried out by a qualified electrician in accordance with the 

regulations in force locally.

 

f

Only use connecting cables that are suitable with the environmental conditions and 

which meet the construction requirements. (see accessories catalogue)

 

f

If the device is not equipped with a connecting cable and a plug, or other means for 

disconnecting from the mains with a contact opening on each pole according to the 

conditions of the overvoltage category III for full disconnection, a disconnecting 

device of this type must be incorporated into the permanently installed electrical 

installation according to the wiring rules.

 

f

Do not mount the connecting cables near hot surfaces.

 

f

A plug for the disconnection of the motor from the power supply must be accessible 

after installation.

 

f

Damaged connecting cables must be replaced by GEIGER connecting cables of the 

same type.

 

f

The device must be mounted as described in the installation instructions. Fixations 

shall not be made with adhesives since they are regarded as unreliable.

Содержание SOLIDline GU45 Series

Страница 1: ...bly and operating instructions Notice originale de montage et d utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento Tubular motor GEIGER SOLIDline Motor control GEIGER Touch GU45 M for rolling shutters awnings and screens ...

Страница 2: ...al information Dear customer By purchasing a GEIGER motor you have decided on a quality product from GEIGER Thank you very much for your decision and the confidence placed in us Before you put this drive into operation please observe the following safety instructions It serves for the prevention of danger and for the avoidance of personal injury and damage to property The installation and operatin...

Страница 3: ...w cleaning are to be carried out in the vicinity f Disconnect the automatic controlled device from the mains power supply if opera tions such as for example window cleaning are being carried out in the vicinity f During operation observe the danger zone f Do not use the installation if people or objects are in the danger zone f Urgently shut down damaged installations until repair f Unconditionall...

Страница 4: ...and any other fixed element f The rated speed and the rated torque of the motor must be compatible with the device f The mounting accessories that are used must be designed in accordance with the selected rated torque f Good technical knowledge and good mechanical skills are necessary for the motor installation Incorrect installation can lead to serious injury Electrical work must be carried out b...

Страница 5: ... shaft adapter Insert roller capsule on the opposite side Put shaft with motor on motor support or on pivoting engine bearer On the opposite side pull out roller capsule until bolt fits into ball bearing Screw together roller capsule with shaft Screw together shaft with tubular carrier Fix rolling shutter casing to shaft Installation into awnings and screens Insert motor with a suitable adapter an...

Страница 6: ...ervice clamps may be accom plished only by an electrical specialist When changing the running direction the switchover must be effected through an off position When changing the running direction the switchover time must be at least 0 5 s PVC cables are not suitable for equipment used outdoors or exposed to prolonged high levels of UV radiation These cables should not be used if they are likely to...

Страница 7: ...ting button Move up the rolling shutter to the required end position Once the required position is reached move down the rolling shutter about 3 seconds one tube rotation The upper end stop is thus adjusted Stop the rolling shutter and press again the setting button Move down the rolling shutter to the required end position Once the required position is reached move up the rolling shutter about 5 ...

Страница 8: ...nwards The control leads are interchanged Exchange black brown control leads Motor only runs in one direction Motor in the end position Run motor in the opposite direction After running several times the motor breaks down and no longer responds The motor became too hot and has switched off Try it again after a cooling time of about 15 min The adjusted end position is not correct Adjusting knob not...

Страница 9: ...14 30 EU 2014 53 EU 2011 65 EU EU 2015 863 EU 2017 2102 Applied standards DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 0700 1 Ber 1 2014 04 EN 60335 1 2012 AC 2014 EN 60335 1 2012 A11 2014 DIN EN 60335 2 97 VDE 0700 97 2017 05 EN 60335 2 97 2006 A11 2008 A2 2010 A12 2015 DIN EN 62233 VDE 0700 366 2008 11 EN 62233 2008 DIN EN 62233 Ber 1 VDE 0700 366 Ber 1 2009 04 EN 6...

Страница 10: ...y T 15 C 70 C dry and non condensing place 1 SOLIDline COM 3 5 mm SOLIDline SOC 3 mm SOLIDline SIL 0 mm without trunnion 2 The average sound pressure level data are intended for guidance only The values were determined by GEIGER at a distance of 1 m with a hanging motor at idle speed and averaged over 10 seconds There is no reference to any specific test standard Subject to technical modifications...

Страница 11: ...11 www geiger de EN EN ...

Страница 12: ...n EN EN For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you Gerhard Geiger GmbH Co KG Schleifmühle 6 D 74321 Bietigheim Bissingen T 49 0 7142 9380 F 49 0 7142 938 230 info geiger de www geiger de ...

Отзывы: