9. What to do if…
Problem
Solution
Motor does not run.
• Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist
electrician.
Instead of in the upwards direction, motor
runs downwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
The adjusted end position
is not correct.
• Adjusting knob not pressed properly.
Repeat adjustment process, press adjus-
ting knob deeply.
• Actuator does not rotate simultaneously.
Push shaft onto tube actuator, repeat
adjustment process.