IT

Venetian blind motor: 

GEIGER RESCUEline (GJ5606 AE100) 

with electronic control and battery operation

For Venetian blinds and exterior blinds

Содержание GJ5606 AE100

Страница 1: ...ns Notice originale de montage et d utilisation Instrucciones originales de instalación y funcionamiento Istruzioni originali di installazione e funzionamento EN FR ES IT Venetian blind motor GEIGER RESCUEline GJ5606 AE100 with electronic control and battery operation For Venetian blinds and exterior blinds ...

Страница 2: ...tallation contrary to the installation and operating instructions and or constructional modification the legal and contractual guarantee for property damage and product liability lapses Index 1 General information 2 2 Guarantee 2 3 Intended use 3 4 Safety instructions 3 5 Safety Instructions for batteries 4 6 Safety instructions for assembly 4 7 Assembly note 6 8 Installation instructions 7 9 Elec...

Страница 3: ...ning are being carried out in the vicinity f f During operation observe the danger zone f f Do not use the installation if people or objects are in the danger zone f f Urgently shut down damaged installations until repair f f Unconditionally shut down the unit during maintenance and cleaning operations f f Pinching and shearing points are to be avoided and must be secured f f This appliance can be...

Страница 4: ...al medical attention Leaking battery fluid can cause skin irritation and burns f f If the battery is damaged or used improperly vapours may be emitted Allow for fresh air and consult a doctor in case of any discomfort The vapours can irritate the respiratory tract 6 Safety instructions for assembly I I ATTENTION Important safety instructions Follow all installation instructions as incorrect instal...

Страница 5: ...according to the wiring rules f f Do not mount the connecting cables near hot surfaces f f A plug for the disconnection of the motor from the power supply must be accessible after installation f f Damaged connecting cables must be replaced by GEIGER connecting cables of the same type f f The device must be mounted as described in the installation instructions f f Parts that are inserted must be co...

Страница 6: ...ctronic control unit with limit stop switch and a LED display that shows the system status at any time over colour LEDs The system can be connected to a central fire alarm system In case of fire or in the event of an error case the electronic control ensures the immediate opening of the blind in order to clear the emergency exits The system is independent of the supply voltage in the event of fire...

Страница 7: ...e damage to the motor like cracks or open cables I I Before installation it is essential to check the drive and the electronic control for visible damage such as breakage or open cables I I The RESCUEline may only be put into operation if mains voltage is available at the installation site Head rail opening at bottom ...

Страница 8: ...8 Gerhard Geiger GmbH Co KG 100W1590 0519 V001 en EN EN Head rail opening at top ...

Страница 9: ... compartment Please note the warning in chapter 10 Battery replacement 12V connections I I Wires and contacts which are marked with nc not connected have no function Wires without a function are cut at the end of the sheath green yellow or orange and grey Connection of operating and setting switch H H Danger of electric shock Potential free contacts must be used for opera tion and setting Only the...

Страница 10: ...ion is carried out in reverse order Please note f f If battery defective replace battery is displayed the normal driving mode is blocked See section emergency manual operation f f The battery is supplied partially charged After installation the battery is charged in the electronic control unit The charging process takes approx 5 hours The device is then ready for use f f Under a protective sticker...

Страница 11: ...erence run P P Learning run upper end position P P Learning run lower end position P P Shutdown by overload protection Flashing signals simultaneous flashing of various colour LEDs p Freezing protection activated 3 C p Defective battery replace battery p No mains voltage p p Ambient temperature too high battery 45 C p p Ambient temperature too low battery 0 C p p Battery has reached critical level...

Страница 12: ...charge state If the battery charge drops below the critical battery capacity the drive retracts the curtain in the upper end position and then a bit downwards so that the battery can be replaced Yellow and red LEDs flash alternately Operating mode Minimum operating temperature not reached If the operating temperature falls below the minimum permissible operating temperature the system runs automat...

Страница 13: ... on delivery Note If the motor is installed in a closed Venetian blind and if the limit stop switch is used the motor can be operated without further settings I I If the factory setting has been carried out and if the programming mode is activated max 100 revolutions can be done downwards Reset to factory settings for a further run downwards 13 Activate the programming mode I I Prerequisite The mo...

Страница 14: ...eted From now on the drive always moves against the limit stop switch Cancel the programming mode In order to cancel the programming mode press the programming keys programming key UP DOWN keys limit stop switch and DOWN key until the motor confirms the cancellation of the programming mode after about 3 seconds with 2 x click clack 15 Referencing on the limit stop switch The referencing on the lim...

Страница 15: ...afe charging of the battery this will be indicated on the LED display Temperature too high green and yellow LEDs flash Temperature too low green and red LEDs flash The blind can still be operated until the critical battery status is reached As soon as this happens the blind is moved to the upper position and remains there until the battery is fully charged Yellow and red LEDs flash 19 Recommission...

Страница 16: ...s in one direction Motor in the end position Run motor in the opposite direction Readjust the end positions if necessary After running several times the motor breaks down and no longer responds The motor became too hot and has switched off Try it again after a cooling time of about 15 min Critical battery capacity Observe LED status display The blind is in the upper position actuates the limit sto...

Страница 17: ... EC 2014 30 EU 2014 53 EU 2011 65 EU Applied standards DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 0700 1 Ber 1 2014 04 EN 60335 1 2012 AC 2014 EN 60335 1 2012 A11 2014 DIN EN 60335 2 97 VDE 0700 97 2017 05 EN 60335 2 97 2006 A11 2008 A2 2010 A12 2015 DIN EN 62233 VDE 0700 366 2008 11 EN 62233 2008 DIN EN 62233 Ber 1 VDE 0700 366 Ber 1 2009 04 EN 62233 Ber 1 2008 DIN...

Страница 18: ...sions 220 mm Diameter 55 mm Weight without battery 0 30 kg Battery Type LiFePo4 Capacity 14 08 Wh 1 1 Ah Charging temperature range 0 C to 45 C Operating time in case of mains voltage failure UPS operation 4 min battery mode Battery buffer 6 Wh incl reserve at 12 VDC 0 5 Ah 500mAh Weight 0 20 kg Indoor LED display Dimensions 53 x 13 x 8 mm L x H x B Outdoor LED display Dimensions 57 x 17 x 17 mm L...

Страница 19: ...Right electronic control without battery M56F155 Adjustment switch M56F156 Battery for electronic control type 4IFR19 66 M56F157 Outdoor LED display L 500 mm M56F158 Indoor LED display L 3000 mm M56E845 Connection cable L 500 mm with STAS 3 M56E846 Connection cable L 900 mm with STAS 3 M56E847 Connection cable L 3000 mm with open end cable M56E789 For connection to the LED display with plug and op...

Страница 20: ...n EN EN For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you Gerhard Geiger GmbH Co KG Schleifmühle 6 D 74321 Bietigheim Bissingen T 49 0 7142 9380 F 49 0 7142 938 230 info geiger de www geiger de ...