14. Programming/changing the end stops
The upper and lower end stops can be programmed and changed independently
of each other.
• Activate the programming mode.
• Run the motor in the direction of the desired end
position. The motor interrupts its run just to show that it
is in the programming mode:
• The direction in which the motor moves after the break*
determines the end stop to be programmed.
(UP = upper end stop, DOWN = lower end stop)
• When the desired end position is reached, move the
motor in the opposite direction until 2 short breaks*
show the last saved position.
• The programming is completed.
* As long as the interruption of movement has not yet
occurred, corrections can be done.
Start the setting process again to adjust another end position.
The referencing is automatically activated if the upper end position is programmed.
Limit stop switch instead of upper end position
• If the direction of rotation UP is to be switched off via the limit stop switch, no upper end
position may be learned. The blind moves against the limit stop switch every time.
• If an upper end position has already been learned and is now to be switched off via the
limit switch, the learning mode must be activated and the blind moved against the limit stop
switch. The lower end position is unchanged and the programming is completed.
• From now on, the drive always moves against the limit stop switch.
Cancel the programming mode:
In order to cancel the programming mode, press the programming keys (programming key/UP/
DOWN keys/limit stop switch and DOWN key) until the motor confirms the cancellation of the
programming mode after about 3 seconds with 2 x click-clack.
15. Referencing on the limit stop switch
The referencing on the limit stop switch can compensate a possible drifting of the upper end
position due to the modified winding behaviour of the lifting tapes.
If the referencing has been activated (see below), the next UP run is done till the limit stop
switch.
The variation in distance between the upper limit position and the limit stop switch is stored.
After 1, 5, 20 and then every 50 cycles on the upper end stop, the motor runs against the limit
stop switch in order to test if the variations in distance have changed. If this is the case, the
upper end position is readjusted.
The motor stops on the limit stop switch by the reference runs.
16. Enable/disable reference cycles
The referencing is enabled on delivery.
The referencing can be enabled only if the upper end
position is set on position.
Switching on/off referencing:
Press the programming keys (programming key/UP/DOWN keys/limit stop switch and DOWN
key) between 6 and 9 seconds until the motor jerks 1 x after about 3 seconds and another time
after 6 seconds for feedback “Switching on/off referencing”.
A subsequent UP command with 1 x jerking enables the referencing, a DOWN command with
2 x jerking disables it.
PROG
PROG