64
AGy -L
Eng
lish
Term. Designation
Function
1
Digital Output 4-NO
2
Digital Output 4-COM
Programmable digital relay output, default: [2] Drive OK (max 1A 30Vdc/250Vac)
3
Digital Output 4-NC
4
Digital Input 8
Programmable digital input - Default: Fault Reset src
5
Digital Input 7
Programmable digital input - Default: Ext fault src
6
Digital Input 6
Programmable digital input - Default: Freq Sel 3 src
7
Digital Input 5
Programmable digital input - Default: Freq Sel 2 src
8
COM-IN Digital Inputs
Supply reference for Digital inputs (max 6mA @ +24V)
9
+ 24V OUT
+ 24 V potential voltage reference (max 300mA)
10
0 V 24 - GND Dig. Inputs
0 V 24 reference for Digital inputs
11
0 V 24 - GND Dig. Inputs
0 V 24 reference for Digital inputs
16
Digital Output 1
Programmable digital output - Default: [51] Contactor
17
Digital Output 2
Programmable digital output - Default: [32] Freq<thr1
Term. Designation
Function
18
Digital Output 3 - NO
19
Digital Output 3 - COM
Programmable digital relay output
Default: [54]Brake cont, (max 1A 30Vdc/250Vac)
20
Digital Output 3 - NC
21
GROUND REF
Ground shield cable reference
22
Digital Input 1
Programmable digital input - Default: Enable src
23
Digital Input 2
Programmable digital input- Default: Run Fwd src
24
Digital Input 3
Programmable digital input - Default: Run Rev src
25
Digital Input 4
Programmable digital input - Default: Freq sel 1 src
26
Analog Output 1
Programmable analog output - Default: [0] Output freq, (±10V / max 5mA)
27
Analog Input 2
Programmable VOLTAGE analog input - Default: n.a. , (±10V / max 0,5mA)
28
Analog Input 3
Programmable CURRENT analog input -
Default: n.a. ,
( max 20mA)
29
+10V OUT
+ 10 V potential voltage reference, (max 10mA)
30
Analog Input 1
Programmable VOLTAGE analog input -
Default: n.a. ,
(±10V / max 0,5mA)
31
0 V 10 - GND
0 V 10 reference for analog inputs/outputs
32
-10V OUT
- 10 V potential voltage reference, (max 10mA)
33
Analog Output 2
Programmable analog output - Default: [2] Output curr,
(±10V / max 5mA)
34
COM Digital outputs
Common reference for Digital outputs (open-collector)
n.a. = not assigned
+24Vdc voltage, which is used to externally supply the regulation card has to be stabilized and with a
maximum ±10% tolerance. The maximum absorption is 1A.
It is not suitable to power supply the regulation card only through a unique rectifier and capacitive filter.
ENC-EXP-AGy card
The EXP-ENC-AGy card allows the connection of a digital encoder TTL (+5V) or HTL (+24V)
Default setting = HTL (+24V).
See chapter 8 - Encoder Interface - for further information.
Caution
Содержание SIEIDrive LIFT AGy -L
Страница 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Страница 46: ...Italiano 46 AGy L ...
Страница 90: ...English 90 AGy L ...
Страница 134: ...Français 134 AGy L ...
Страница 178: ...Deutsch 178 AGy L ...
Страница 222: ...Español 222 AGy L ...
Страница 240: ...NOTE ...
Страница 241: ......