Continued from the previous page
EDID Mode Selection
1. EXTERNAL
MODE:
In EXTERNAL mode, the Extender for HDMI 1.3 Over One Fiber With IR
uses EDID collected during initial power-up from the display device. To
activate this mode, make sure that the EDID Mode switch is in the OFF
position (see page 9 for instructions). If EDID is unavailable from the external
display device or other EDID-related problems are encountered (such as the
source losing power and being unable to receive EDID from the display), use
LOCAL Mode instead.
2. LOCAL
MODE:
In this mode, the Extender for HDMI 1.3 Over One Fiber With IR collects and
memorizes the EDID of a display device upon power-up, then plays back
this EDID to connected sources whenever they need it. To use this mode,
set the EDID Mode Switch to ON (see page 9).
Fiber Calibration
Calibrating a Fiber Optic Cable:
1. Make sure the Calibration switches on both Sender and Receiver units are in
the OFF position (See page 9).
2. Connect
the
fi
ber optic cable assembly between Sender and Receiver units.
Connect power to both Sender and Receiver units.
3. The Calibration process will commence. Calibration LEDs will blink fast
at
fi
rst then slower as the process
fi
nishes. The Calibration LEDs on the
Sender and Receiver will turn GREEN when the process is
fi
nished (this
process may take up to 60 seconds).
4. Once Calibration has taken place and video is observed to be clean and
uninterrupted on display devices, place DIP switches for the Calibration
function into the ON (LOCK) positions on both Sender and Receiver. The
Extender will now skip the calibration process when powering up on subse-
quent occasions.