Swivel Arm Hoist
GEDA STAR 200 STANDARD / GEDA STAR 250 COMFORT
11.3 Safety inspection
Before starting work
Carry out a test run with
empty
load suspension device and check whether the entire length
of travel is clear.
The actuator must be stopped immediately if
-
an EMERGENCY STOP button is pressed
-
the load hook has reached the limit switch bow in front of the cable drum.
-
the direction button for UP or DOWN is released.
11.4 Operating the swivel arm hoist
NOTE
The swivel arm hoists for GEDA-STAR 200 STANDARD and GEDA-STAR 250 COMFORT
have
a speed level
of max. 28 m/min. (22 m/min. on GEDA STAR 200 STANDARD)
The swivel arm hoist can only be controlled in jog mode.
Unlock EMERGENCY STOP button (1) on manual control.
Load
up
-
Press UP button (2).
Load
down
-
Press DOWN button (3).
Switch off or stop:
-
Release UP button (2) or DOWN button (3).
In an emergency by operating the EMERGENCY STOP button
(1).
1
2
3
Fig. 24 Operating/control
NOTE
If the swivel arm hoist is to be operated from below, then this can be done by plugging in
manual controls with long cables of 30 m or 50 m (accessories).
11.5 Interruption/end of work
Move load suspension device down to lower position with the DOWN button and unload.
Unplug manual control (if possible) and keep safe.
Remove mains plug.
11.6 Shutting down in an emergency
In situations that present a risk for the operating personnel or the lift, shutdown the lift by
pressing the EMERGENCY STOP button.
-
There is an EMERGENCY STOP button located at each control point.
Assembly and Operating Manual
Page 26 of 38
BL107 GB Edition 01.2010