Swivel Arm Hoist
GEDA STAR 200 STANDARD / GEDA STAR 250 COMFORT
6.1.3 Manual control
Operation of the manual control is the same for all swivel arm hoists.
-
The cable is 2 m long.
-
On the GEDA STAR 250 COMFORT, the cable is pluggable.
1 = EMERGENCY STOP button
2 = UP button
3 = DOWN button
4 = suspension clamp
1
2
4
3
Fig. 5 Manual control
7
Transport
Check the shipment for transport damages and for completeness according to your order.
Immediately inform the carrier and handler if there are transport damages!
8
Requirements for the site of installation
Fastening option
The swivel arm hoist is secured on/in the building or scaffold by a fastening device.
-
Ground, floor or scaffold must have sufficient fastening options and bearing capacity.
8.1
Electrical connection (on site)
A building site main cabinet with residual current circuit breaker with 230 V, 50 Hz and
16 A slow-to-blow fuse must be provided by the customer.
-
Connect a rubber hose line 3 x 2.5 mm² as a mains feed line directly to the building site main
cabinet without any adapters from other power consumers, in order to avoid a drop in
voltage and thereby a loss of motor power.
NOTE
If the power supply is poor, unplug any other current consumers.
Plug mains plug into on-site power supply and plug in manual control on GEDA STAR
250 COMFORT. - The swivel arm hoist is operational.
Assembly and Operating Manual
Page 14 of 38
BL107 GB Edition 01.2010