12
Connection high voltage accessories: in.yt
These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all
connections, including ground Depending on where the connections are made on the spa pack PCB, 120 V and
240 V accessories are supported Refer to the following tables for correct connections Note that all female terminals
must be correctly and completely seated on the PCB tab for proper current ratings
Pump 2 (A2)
Voltage
120 V 240 V
Green / ground
P51
P51
Black / low speed
K6-P K6-P
Red / high-speed
K3-P
K3-P
White / common
P60
P71
Pump 5 (B3)
(in.yt-12 only)
Voltage
120 V 240 V
Green / ground
P115
P115
Black / line
K24-P K24-P
White / common
P121
P127
Blower (B4) (in.yt-12 only)
Voltage
120 V 240 V
Green / ground
P114
P114
Black / line
K25-P K25-P
White / common P120
P126
Direct output 2 (C1)
(in.yt only)
Voltage
120 V
240 V
Green / ground
P92
P92
Black / line
P133
P133
White / common
P86
P80
Pump 3 (C3)
(in.yt-7 and in.yt-12)
Voltage
120 V 240 V
Green / ground
P94
P94
Black / low speed K22-P K22-P
Red / high-speed K21-P K21-P
White / common
P88
P82
Circ. pump (C2)
(in.yt-7 and in.yt-12)
Voltage
120 V 240 V
Green / ground
P93
P93
Black / line
K23-P K23-P
White / common
P87
P81
Auxiliary (B1)
(in.yt-12 only)
Voltage
120 V
240 V
Green / ground
P118
P118
Black / line
K26-P K26-P
White / common
P124
P130
Light (12 V AC, 1A Max.)
Voltage
Always on
P34
Relay
P35
Pump 1 (A3)
Voltage
120 V 240 V
Green / ground
P49
P49
Black / low speed
K2-P
K2-P
Red / high-speed
K4-P
K4-P
White / common
P58
P69
Pump 4 (B2)
(in.yt-12 only)
Voltage
120 V 240 V
Green / ground
P118
P118
Black / low speed K26-P K26-P
Red / high-speed K27-P K27-P
White / common
P123
P129
Ozonator (A1)
Voltage
120 V 240 V
Green / ground
P52
P52
Black / line
K1-P
K1-P
White / common
P61
P72
Direct output 1 (A4)
Voltage
120 V
240 V
Green / ground
P47
P47
Black / line
P32
P32
White / common
P56
P67
This table shows typical connections OEMs may have a different connection scheme
Y Series connections