11
Pump 2 (A2)
Voltage
120 V 240 V
Green / ground
P51
P51
Black / low speed
K6-P
K6-P
Red / high-speed
K3-P
K3-P
White / common
P60
P71
Blower (A4) (in.ye-5 only)
Voltage
120 V 240 V
Green / ground
P48
P48
Black / line
K6-P
K6-P
White / common
P57
P68
Pump 3 (A4) (in.yt-5 only)
Voltage
120 V 240 V
Green / ground
P48 P48
Black / low speed
K6-P K6-P
White / common
P57 P68
Circ. pump* (A1)
Voltage
120 V 240 V
Green / ground
P52
P52
Black / line
K1-P
K1-P
White / common
P61
P72
Light (12 V AC, 1A Max.)
Voltage
Always on
P34
Relay
P35
Pump 1 (A3)
Voltage
120 V 240 V
Green / ground
P49
P49
Black / low speed
K2-P K2-P
White / common
P58
P69
Ozonator* (A1)
Voltage
120 V 240 V
Green / ground
P52
P52
Black / line
K1-P
K1-P
White / common
P61
P72
Direct output 1
(in.ye-5 only)
(Floating connector)
Voltage
120 V 240 V
Green / ground
P47
P47
Black / line
P32
P32
White / common
P56
P67
This table shows typical connections OEMs may have a different connection scheme
* Ozonator and circ pump can be combined on the same output via the optional splitter PP1
A3
A4
A1
A2
OPTIONAL
PP1 SPLITTER
HIGH SPEED (RED)
LOW SPEED (BLACK)
COMMON (WHITE)
GROUND (GREEN)
LIVE (BLACK)
COMMON (WHITE)
GROUND (GREEN)
---
RED
WHITE
BLACK
GREEN
INPUT VOL
TAGE
HEATING
ELEMENT
HEATER
GROUND
L1
N
L2
120V 240V
A0
120V DIRECT
K3
K4
K6
K7
K9
K10
P5
P17
P7
P22
P23
P28 P30
P33 P36
P37
P34
P18
P19
P6
P2
P3
P4
P8
P24
P29
P38
P41
P42
P45
P35
30A/480V
AC TIME-DELA
Y
CLASS G
F2
20A/600VAC TIME-DELAY
CLASS G
30A/480VAC TIME-DELAY
CLASS G
F3
F1
F4
1
2
3
4
0.5A/250VAC
3AG FAST-ACT.
P
K1
K2
P39 P40
P43 P44
P
P
P
P
CO
C1
CO
P9
P10
P11 P13
P14 P15
P21
P32
P31
C
C
P12
P25
P46
P66
P47
G
N
L2
P48
P49
P50
P51
P52
P53
P56
P57
P58
P59
P60
P61
P62
P67
P68
P69
P70
P71
P72
P73
P55
P
P76
P77
P26 P84
P16
P79
P78
P83
TRANSFORMER
LIGHT, SWITCHED
HL & TEMP.
PROBE
IN.FLO
SENSOR
MAIN KEYPAD
COMMUNICATION LINKS
LIGHT, DIRECT
High voltage accessory connections
Two options are available with Y Series spa packs for connecting high voltage accessories: 0250” quick-connect
terminals, or AMP pins and housings
Connection high voltage accessories: in.ye
These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all
connections, including ground Depending on where the connections are made on the inye pack PCB, 120 V and
240 V accessories are supported Refer to the following tables for correct connections Note that all female terminals
must be correctly and completely seated on the PCB tab for proper current ratings
Y Series connections