Phosphoric acid
or muriatic acid
Refer to acid manufacturer's instructions.
Wear eye protection and rubber gloves during these
operations. Splashing or spilling acid can cause
severe personal injuries and/or property damage.
Always work in a well-ventilated area.
Always add acid to the water; never add water
to the acid.
Do not pour acid outside of the unit where
the connectors are located.
Never use acetic acid to clean the cell, as this will
cause permanent damage to cell components and
void the warranty.
In.clear includes a self-cleaning feature to prevent scale
deposits on the graphite electrodes of the in.clear
system. However, deposits may still form due to hard
water. If that happens the cell should be cleaned in an
acidic solution.
All power must be disconnected before any service
procedure is performed.
Disconnect the communication cable and power cable
of the in.clear unit.
To clean the in.clear cell, follow these steps:
• To remove scales from the cell, we recommend
using phosphoric acid (non-diluted) as the preferred
cleaning product.
• Close the spa flow shut off valves. Unscrew both
unions from the unit and remove the cell from
the spa equipment compartment.
• Install the rubber washer and the plastic nut on the
threaded end of the cell. Tighten plastic nut firmly.
• Place the cell vertically with the cap end down into
a plastic 19 L (5 U.S. gallon) bucket and carefully
pour the acid solution into the cell until the 4 plates
are covered (careful not to overflow). The acid
solution will begin to produce bubbles to clean
the electrodes.
A foaming action will follow, which is caused by
the scale deposits being dissolved from the plates.
If rigorous foaming action does not begin, the cell
does not need to be cleaned. Rinse and reinstall
the cell.
• Allow the electrodes to remain in the solution until
the foaming has stopped. However, DO NOT leave
in acid for more than fifteen minutes. Excessive acid
cleaning will damage the electrolytic cell.
• Pour the acid solution back into the bucket and rinse
the cell thoroughly with clean tap water. If deposits
are still visible, repeat operation for fifteen minutes
maximum (some acid may need to be added to
the solution).
• Remove the plastic nut and washer from the cell
and keep them for future cell cleaning.
• Rinse the in.clear with fresh water.
• Re-install the in.clear unit into spa system plumbing,
tighten all connections by hand. Open the spa flow
shut off valves.
• Reconnect the keypad and power cable.
• Turn power on and start up the pump. Check the
keypad to see that the bromine generation LED is
on and resume normal operation.
Cell cleaning
Содержание in.clear 0605-500002