in.clear user manual
11
Diagnostic mode
Diagnostic mode can be
used to periodically adjust
the sodium bromide
level or to check sodium
bromide keypad warnings
and errors.
The BromiCharge Gauge
will indicate the level of
sodium bromide in the
spa water. As you add
sodium bromide to the
spa an animation will
indicate rising levels*.
If the levels go down
(when adding fresh
water, for example) the
animation will indicate
diminishing levels.
Press the Prog key to exit
diagnostic mode or the
system will automatically
exit after 15 minutes.
*In older versions a
number will be displayed
instead of an animation to
indicate the level.
The target number is 12.
Boost key
The first press of the Boost
key turns the in.clear ON
and puts the in.clear into
maintenance mode.
ON appears on the
keypad display.
Press the Boost key once
while in maintenance
mode to start a boost,
or to adjust boost settings.*
The Bromine Generation
Indicator (LED), located
above the Boost key,
lights up when the cell is
producing bromine and
is off when no bromine is
being produced.
Program key
Press and hold
the Program key for
2 seconds to change the
maintenance mode level.
Once in maintenance
mode adjustment, press
the Program key again
to view the suggested
minimum filtration time *
(stand alone version only).
Press the Program key
once more for Diagnostic
mode.
* Not displayed in older
versions.
+ / - Keys
Use the Up and Down
keys to adjust the
maintenance and boost
levels while in the
appropriate mode.
Water must be
circulating through the
in.clear cell in order for
the diagnostic mode
to work. If no water
is circulating through
the in.clear unit, a FLO
message will appear
on the keypad display.
Make sure the pump
is circulating water
through the in.clear.
Be aware that the
gauge will move
according to sodium
bromide level.
Make sure your water
temperature is at least
32° C (90° F).
BromiCharge gauge
BromiCharge gauge (LEDs)
In diagnostic mode, the BromiCharge gauge (LEDs) indicates the approximate
sodium bromide level of your spa water. Do not add sodium bromide if the indicator
is in the green zone.
When adding sodium bromide, the gauge indicator will gradually shift to the right.
When adding clean water to the spa the indicator will shift to the left. In order to
achieve the proper level, start pumps and add 227g (.5 lb) at a time and always allow
5 minutes for the gauge to react before adding more sodium bromide.
The green zone in the center area of the gauge should be targeted for optimal performance.
increase
decrease
Keypad functions
Press and hold the Boost
key for 2 seconds to turn
the in.clear off. OFF will
appear on the keypad
display. Do not turn the
in.clear off unless required
for maintenance, or if
advised by a technician
or Gecko representative.
Turning the in.clear off will
cancel the boost.
Note: With the standalone
version the Bromine
Generation indicator will
blink if the in.clear system
cannot generate bromine
due to low or no water
flow.
* In older versions,
pressing the Boost key
during a boost cycle will
cancel the remainder of
that boost cycle and return
the in.clear system to
maintenance mode.