14
in.clear user manual
FLO error (out of
diagnostic mode)
With the linked version
the FLO error appears
when the in.clear's
pressostat is open for
longer than 3 minutes and
the pump associated with
it was activated by the spa
pack.
Verify that the in.clear unit
was installed on the right
pump (must be installed
on the circulation pump if
present).
Check that the in.clear is
installed on the pressure
side of the pump and that
water is flowing through
the in.clear unit.
Communication Error
The Co error indicates
that a linked version of
the in.clear is being used,
but a pack cannot be
detected. Ensure that you
are using a compatible
pack with appropriate
software, and that all
connections are secure.
If this does not clear the
message, contact your
dealer for help.
High Sodium Bromide
Warning
High Sodium Bromide
Warning (Hi) occurs
when too much sodium
bromide is present in the
water or there is a high
TDS level (water hardness,
alkalinity, organic
compounds, etc).
To clear a High Sodium
Bromide Warning,
readjust the sodium
bromide content of your
water in diagnostic mode,
into the green zone by
draining some water from
your spa and adding fresh
water.
in.clear is turned off
The OFF message
indicates that the in.clear
is turned off.
Press the Boost key to
reactivate the in.clear.
Troubleshooting