Flo & UPL error conditions step-by-step
FLO
Primary pump is activated but
the system doesn't detect any
water flow
• Make sure water valves are
open and that water level is
high enough.
• Check and remove anything
obstructing the filter.
• Make sure there are no
air locks (or that no object
obstructs the passage of
water in the heater channel).
Pumps may make strange
noises.
Follow air lock procedure to
clear them.
• Make sure that the pump
associated to the heater
(primary pump) is running.
• Make sure in.flo™ cable
(located above the heater)
is properly connected.
• If problem persists replace
heater.
• If the problem is not solved
replace Spa Pack.
in.flo™ cable
• New low level configuration
software needs to be
downloaded into the in.xe™
spa system, without it the
system will not be operable.
• Contact our toll free line
for technical support
(
1-800-784-3256
).
Note: this line is dedicated
to assist authorized service
technicians and dealers only.
No low level configuration software
in system!
Step-by-Step