Checking the backpressure
sensor
1
Demount the cover plate. → See
1
2
Loosen the control unit and fold it forwards.
3
Short-circuit both of the backpressure
sensor’s metal brackets on the rear of the
control unit with an electrically conductive
object.
✓ If the backpressure sensor is working,
the status LED lights up red, the buzzer
sounds and the fault is displayed in the
Geberit Control app.
4
Check the metal brackets for scaling. Clean
with a soft cloth and descaling agent if
required.
ATTENTION
Surface damage caused by scratching
Risk of corrosion if the gold-plated surface of the
metal brackets is damaged.
▶ Do not clean the metal brackets with abrasive
or scratching tools.
5
Plug the control unit into the retainer.
6
Snap the control unit into place.
7
Mount the cover plate. → See