Other functional errors
The following table will help you with troubleshooting if individual functions of the shower toilet
have failed.
The shower toilet can be used as a normal toilet even in the event of a malfunction.
The spray arm must be fully retracted. You start the toilet flush as usual by pressing
the actuator buttons.
If the device is defective, switch it off using the power switch.
Description of problem
Cause
Fault clearance
Odour neutralisation is
weak or ineffective.
Ceramic honeycomb
filter dirty
▶ Replace the ceramic honeycomb
filter. → See "Replace the ceramic
honeycomb filter", page 38.
The spray arm is not
functioning correctly.
Malfunction has
occurred
▶ Switch off the device.
→ See "Switching the device on and
off", page 19.
▶ Wait 30 seconds.
▶ Switch on the device.
→ See "Switching the device on and
off", page 19.
Result
✓ The device initialises again after
switching on.
The cleaning effect of the
shower has weakened.
Spray nozzles
clogged or defective
▶ Clean or replace the spray nozzles.
→ See "Clean the spray nozzle",
page 37.
▶ descale the device. → See "Descale
the device", page 40.
When using the shower
function, the shower toilet
no longer reaches the
usual temperature.
Shower toilet dirty
▶ descale the device.
→ See "Descale the device",
page 40.
▶ Switch off the device.
→ See "Switching the device on and
off", page 19.
▶ Wait 30 seconds.
▶ Switch on the device.
→ See "Switching the device on and
off", page 19.
Result
✓ The device initialises again after
switching on.