EN
Operation
Controls
1
Red LED
2
Brightness sensor
3
<Flush time> button
4
<Hygiene> button (interval flush)
Testing the function
After the battery has been inserted or a connection to the mains voltage has been established,
the red LED indicates the status of the urinal flush control.
Red LED
Status
Description/measure
1 short flash pulse, then 2-
second pause
OK
Urinal flush control is functional.
No flash pulses
Fault
Urinal flush control is not functional: check
the battery or mains connection.
3 short flash pulses, then 2-
second pause
Fault
Solenoid valve is not connected to the
control unit: check the cable connection.
2 short flash pulses, then 2-
second pause
Fault
Urinal trap is not connected to the control
unit: check the cable connection.
3 long flash pulses, then 2-
second pause
Fault
Sensor 1 in urinal trap is defective: check
the cable connection or replace the urinal
trap.
4 long flash pulses, then 2-
second pause
Fault
Sensor 2 in urinal trap is defective: check
the cable connection or replace the urinal
trap.