EN
Technical data
Type 501-1 N
Type 501-2 N
Type 1000-2 N
Type 501-1
Type 501-2
Type 1000-2
Nominal voltage
230 V AC
–
Mains frequency
50–60 Hz
–
Mains connection
Two-wire mains cable
–
Battery type
–
CR-P2 (6 V)
Service life of battery supplied
–
~ 5 years
Protection degree
IP54
IP54
Operating temperature
4–30 °C
4–30 °C
Power consumption
1.3 W
1.3 W
Flow pressure
1–10 bar
1–10 bar
100–1000 kPa
100–1000 kPa
Flush time, factory setting
Type 501: 3.5 s
(1 l at 3 bar)
Type 1000-2: 1.5 s
(0.5 l at 4 bar)
Type 501: 3.5 s
(1 l at 3 bar)
Type 1000-2: 1.5 s
(0.5 l at 4 bar)
Interval flush, factory setting
24 h
24 h
Interval flush, adjustment range
24 or 72 h
24 or 72 h
Operating modes
Normal operation
A flush is actuated when use is detected. The flush time can be
set in 6 levels. → See "Setting the flush time", page 19.
Stadium operation
Stadium operation is activated automatically after 4 uses at
intervals of less than 60 seconds between one user and the
next. The flush is actuated every 60 seconds. Stadium operation
is deactivated when more than 60 seconds elapse between
uses.
Interval flush
The interval flush is actuated automatically if the urinal has not
been used for an extended period. This prevents the urinal trap
from drying out (hygiene function). The interval flush is actuated
every 24 or 72 hours, but it can also be deactivated. → See
"Setting the interval flush", page 20.
18014402741989259-1 © 07-2019
968.645.00.0(01)
17
Содержание 501-1
Страница 1: ...OPERATION MANUAL BETRIEBSANLEITUNG MANUEL D UTILISATION ISTRUZIONI DI FUNZIONAMENTO...
Страница 60: ...1 1 2 3 4 5 60 18014402741989259 1 07 2019 968 645 00 0 01...
Страница 61: ...6 2 1 2 18014402741989259 1 07 2019 968 645 00 0 01 61...
Страница 62: ...3 4 3 1 2 NN 62 18014402741989259 1 07 2019 968 645 00 0 01...
Страница 63: ...3 4 NN 5 18014402741989259 1 07 2019 968 645 00 0 01 63...