EN
Setting the flush time
The flush time must be set before the urinal is installed. If the settings need to be changed
later on, the urinal will need to be removed and then reinstalled again by following the
manufacturer’s instructions.
Factory-set flush time:
• type 501: 3.5 seconds = 1 litre at 3–4 bar (level 2 in table below)
• type 1000-2: 1.5 seconds = 0.5 litres at 3–4 bar (level 1 in table below)
Recommended settings:
Type 501
Type 1000-2
Flow pressure [bar]
Flush time [s]
Flow pressure [bar]
Flush time [s]
1–2
7.5
1–1.5
5.5
2–4
5.5
1.5–3.5
3.5
> 4
3.5
> 3.5
1.5
Setting the flush time:
1
Press the <Flush time> button for 1 second.
✓ The flush time setting advances one level. The current setting is shown with flash
pulses as indicated in the table below.
2
Press the <Flush time> button repeatedly for 1 second until the required flush time is
set.
Level
Red LED
Flush time [s]
Approximate flush volume at
3–4 bar [l]
1
1 flash pulse
1.5
1)
0.5
2
2 flash pulses
3.5
1
3
3 flash pulses
5.5
1.5
4
4 flash pulses
7.5
2
5
5 flash pulses
11.5
3
6
6 flash pulses
15
4
1)
Type 501: Only use with a flow pressure of > 5 bar.
Each cycle of setting options ends once the button has been pressed 6 times. The
next time the button is pressed, the setting options start from the beginning again.
18014402741989259-1 © 07-2019
968.645.00.0(01)
19
Содержание 501-1
Страница 1: ...OPERATION MANUAL BETRIEBSANLEITUNG MANUEL D UTILISATION ISTRUZIONI DI FUNZIONAMENTO...
Страница 60: ...1 1 2 3 4 5 60 18014402741989259 1 07 2019 968 645 00 0 01...
Страница 61: ...6 2 1 2 18014402741989259 1 07 2019 968 645 00 0 01 61...
Страница 62: ...3 4 3 1 2 NN 62 18014402741989259 1 07 2019 968 645 00 0 01...
Страница 63: ...3 4 NN 5 18014402741989259 1 07 2019 968 645 00 0 01 63...