Table 4:
Parameters
Menu item
[EN]
[DE]
Description
Application
Adjustment
range
Factory
setting
40
[FlshTime]
[Spülzeit]
Set flush time.
Duration of the flush after one use
Optimum flushing out of
the urinal ceramic
3–15 s [...]
4 s [4]
41
[DetectT]
[VerweilZ]
Set detection time.
Minimum detection time within the
detection range to be recognised as
a user
Prevents flushes due to
unintentional entry of a
person into the
detection range
3–15 s [...]
7 s [7]
42
[DelFollwF]
[FolgVerzö]
Set delay of follow-up flush.
The set parameter is active if menu
item 36 "Select follow-up flush" is set
to [ON] [EIN]
–
1–24 h [...]
2 h [2]
43
[IntFlushT]
[IntervSpZ]
Set interval flush – flush time.
The set parameter is active if menu
item 32 "Select interval flush" is set to
[ON] [EIN]
–
3–180 s [...]
5 s [5]
44
[IntervalT]
[IntervalZ]
Set interval flush – flush interval.
The set parameter is active if menu
item 32 "Select interval flush" is set to
[ON] [EIN]
–
1–168 h [...]
24 h [24]
45
[CleanTime]
[ReiniZeit]
Set cleaning time.
Defines the duration of the inactivity
of the control when the menu item
25 [CleanMode] [Reinigung] is started
–
1–16 min [...]
10 min [10]
Содержание 115.817.11.5
Страница 1: ...Instandhaltungsanleitung Manuel d entretien Istruzioni per la manutenzione Maintenance Manual...
Страница 11: ...EN 11 D64372 001 12 2013 966 444 00 0 00 5 6 3 2 1 90 90 2 mm...
Страница 14: ...EN 14 D64372 001 12 2013 966 444 00 0 00 7 8 Replacing the cover plate 1 2 3 2 1 90 90 2 mm 90 90 2 mm 2 1 3...
Страница 15: ...EN 15 D64372 001 12 2013 966 444 00 0 00 3 4 Replacing the control 1 2 3 2 1 90 90 2 mm 90 90 2 mm 2 1 3...
Страница 19: ...EN 19 D64372 001 12 2013 966 444 00 0 00 9 10 11 12 13 14 15 2 1 1 2 3...
Страница 22: ...EN 22 D64372 001 12 2013 966 444 00 0 00 6 7 8 9 10 11 PH 3 13 mm 13 mm...