Commands
Menu item
[EN]
[DE]
Description
Application
Value
Factory
setting
22
[RangeTest]
[TestErfas]
Check detection range.
The boundary of the detection range
must be crossed in order to check its
function. No flush is released in this
process. The detection range is
without malfunction if the LED in the
sensor window lights up. The function
is deactivated automatically after
10 minutes.
In the event of detection
malfunctions
0–3 [...]
0 [0]
0 Function is deactivated.
1
The sensor for the user detection
range is activated. LED lights
up = user has been detected.
2
The sensor for the manual flush
detection range is activated. LED
lights up = hand has been detected.
3
The sensor for the proximity
detection range is activated. LED
lights up = user movement in the
detection range.
23
[CleanMode]
[Reinigung]
Activate cleaning function.
The control is inactive for the duration
of the entered value from menu item
42 [CleanTime] [ReiniZeit]. The
function is cancelled by re-establishing
connection with the Geberit Service
Handy. The LED in the sensor window
flashes in 3-second cycles.
Actuator plate and WC
can be cleaned without
releasing a flush.
Start = <OK>
–
24
[BlocFlush]
[Blockiere]
Block flush.
No flush is released. Function is
cancelled upon re-establishing
connection with the Geberit Service
Handy. The function is deactivated
automatically after 10 hours.
In the event of detection
malfunctions
Start = <OK>
–
25
[FactrySet]
[Werkeinst]
Reset all functions to factory settings.
In the event of
malfunctions
Start = <OK>
Confirm =
<R>, <OK>
–
8