Operation
Making settings using Geberit Service Handy
The infrared interface for communication with the Geberit Service Handy is located in the middle of the
actuator plate. To enable settings to be made, the Geberit Service Handy must be aimed at the infrared
interface for communication from a distance of 20 to 30 cm and set to bidirectional mode.
²FP
²FP
Figure 2: Operation using the Geberit Service Handy
With the Geberit Service Handy, additional maintenance functions can be performed and individual settings
can be made. The numbers and terms in the column "Menu item" correspond to what can be seen on the
display of the Geberit Service Handy. Further information can be found in the user manual of the Geberit
Service Handy.
Commands
Menu item
[EN]
[DE]
Description
Application
Value
Factory
setting
20
[FullFlush]
[VollMenge]
Release full flush volume.
Triggers a full flush.
For function tests of the
lifting device
Start = <OK>
–
21
[PartFlush]
[TeilMenge]
Release partial flush volume.
Releases a partial flush.
For function tests of the
lifting device
Start = <OK>
–