![GeBe GPT-4352 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/gebe/gpt-4352/gpt-4352_operating-manual_4033186007.webp)
GeBE E + F GmbH • www.oem-printer.com • GeBE Doc.No.: SMAN-E-413-V4.1 Easy-Loading Thermal Printer GPT-4352(-60)
Printer Configuration
7
6 Printer Configuration
6.1 Configuration over Initialisation-TextPreserve "TINIT " (Software Switch)
All commands for initializing the controller are filed in the text file "TINIT ". TINIT is available in the flash memory
of the printer and in the EEPROM (Note: Low-priced controllers with minimal functionality may not have an EE-
PROM). An entry in the EEPROM cancels entries in the Flash. For example, if a printer is to print double height
and inverse in data mode, the relevant commands are entered in the text file "TINIT". After a RESET, the controller
will first carry out its basic initialization, read the solder bridge settings, and then process the commands in the
"TINIT". Therefore, the commands in the "TINIT" have final authority regarding the valid settings. Custom settings
can also be achieved through entries in the text file "TINIT". If an EEPROM is available, "TINIT" can also be alte-
red through an interface.
The basic initialization of the controller corresponds with the following instructions that are initially not entered in
the "TINIT: <ESC> "A"; <ESC> "D" "0"; <ESC> "H" "0"; <ESC> "I" "0";
<ESC> "L" "0"; <ESC> "M" "0"; <ESC> "N" 0 0; <ESC> "P" 1; <ESC> "S"0; <ESC> "W" "0".
6.2 Entries into the "TINIT", which are primarily used
Comm. (ASCII)
Comm. (hex)
Function
<ESC>"Y"n
<ESC> "[" $40$18
1B 59 1E
1B 5B 40 18
Set blackening of the paper to a medium value of 25
Power consumption to 64 pixels, medium print dynamics and print quality
<ESC> "e" $05
<ESC> "r" "1" .... charging circuit configurated for NIMH cells
<ESC> "]" $0 $0
1B 45 05
Power-down after 5 seconds regardless of the buffer status, if enabled
1B 5D 00 00
Activate the transmitter of the serial interface
6.3
Solder Bridges Sleep Mode, Baud Rate, Text/Data Mode, Adapter SELECT
There are four 0-Ohm bridges and two jumpers on the controller board (optional) .
These bridges will each be inquired once during RESET.
Name
Meaning
Comment
Br9
BR204
enable Power
Down
text/data mode
Without Br9, the controller after a Power Up in
sleep modus
Data mode: printing rotated by 180°, first line at the
bottom page margin
Default: connected (disable)
Default: open (text mode)
BR203
BR201/
BR202
RN1
R9
Br206
Br205
RS232/Centr
Baud rate
Choice, if the RS232 or the Centronics through SPI
(GCT-4382-10) is active.
Signal- and
Handhake lines
V ADAPTER
Select
Equipped with TTL levels for the serial interface
Pin 4 of the serial interface can either be connected
with RTS ( Handshake input of the controller) or
with Vcc or Vp (power supply for external interface
adapter)
only connected on version SPI/Centro-
nics
Default: open (OFF)
Other baud rates on request.
Always inquired during RESET.
only connected on version TTL/serial and
SPI/Centronics
Standard: only R9 assembled - Handsha-
ke entry used for wake-up
Option: only Br206 connected - Vp at J2 /
Pin 4
Option: only Br205 connected- Vcc at J2
/ Pin 4
Br221
/DTR_Blue
Over this line the controller sends the signal for
Sleep modus of bluetooth Modul GSW-Blue1.
Default: open -
Option: only Br221 connected -
/DTR_Blue at J2 / Pin 4
Baud
BR201
BR202
Br201, Br202, Br203 closed and Br204 open
Br202, Br203 closed and Br201,Br204 open: activate
the OPD-Menue®
9600
19200
OFF
OFF
ON
OFF
115200
57600
ON
ON
OFF
ON
Jumper J3 zur Auswahl des Power Down Modus
Name
Meaning
Comment
J3
Power Down
Mode
Determines together with Br9, if idle mode,
sleep mode, or power-off mode is going to be
used.
Standard: plugged in = Idle Mode in
combination with assembled Br9.
open = Sleep Mode