GEAX
s.r.l.
Chapter 5
CONTROLS
16
5.1.14
Pump selection
The number of hydraulic pumps that feed the hydraulic system can be
selected: selector D6 allows choosing 1 or 2 pumps.
By varying the capacity, the rotary head basic speed also varies:
•
for normal foundation drilling operations two pumps are used;
•
the use of a single pump slows down the rotary head speed
considerably, thereby making it more suitable for compacted soil with
rock formations (pointed buckets);
•
the use of a single pump simplifies some rotary head rotation
simultaneous controls (e.g. mast lifting and rotation)
•
in CFA mode, is recommended to work with only one pump.
Rotate selector
D6
to choose
whether to feed the hydraulic
system of the rotary table with
one or two pumps.
5.1.14
Disabling the winch limit switches
By pushing button P7, all limit switches are
disabled
The light indicated by the letter
S
warns you that
one or more of the following limit switches has
been disabled:
•
DOWN limit switch of main winch
•
UP limit switch of main winch
•
UP limit switch of auxiliary winch
The limit switches must be disabled only in particular cases: