background image

Product Interface Diagram

Main Tester

Receiver

Remote identifier

05

04

Product Operation Methods

Boot Screen:
Carry out self-checking at the same time (Dotted line dynami-
cally displays the course of self-checking from left to right):

Wait 5 seconds or push any button to display main menu.
Main menu display:

Main Menu Functions

1. Wiremap - Wiring diagram measurement to check end-to-end 

continuity of cables in M, L, R and locate errors.

2. Pair & Length - Pair and measure length for open, short, 

points, verify cable length, open circuit distance.

3. Coax/Phone - Coaxial cable and telephone line.
4. Setup - Calibrate and setup tester.

Note:  Do NOT put live telephone cable into RJ45 port, doing so may

result in burning of testing device.

Wiring Diagram (Wiremap) Test Function

Wiring diagram will carry out wiring diagram (Wiremap) test and
display as follows

Содержание PITS-TP-1

Страница 1: ...receiver is shown in the following RJ11 BNC USB cable is located when inserted into its corresponding port Using the Receiver Install a 9V battery Press the Push to Test key then approach the cables...

Страница 2: ...other wise it may result in damages to the equipment and or personal injury Never conduct testing in thunderstorms to prevent lightning strike and impact which can jeopardize personal safety 10 Unit...

Страница 3: ...ts as follows Pair L The last line 78 indicates no pair was found in lines 7 and 8 Push key to display length of unpaired line number as shown below X will be displayed to indicate an open circuit if...

Страница 4: ...system is widely used on telephone systems computer networking and other related fields Main Tester Receiver Remote identifier Note Due to technical parameters of different brands of cables calibrate...

Страница 5: ...pacity or ambient temperature Technical Specifications Dimension M 185x105x50mm R 218x46x29mm Remote 84x34x27mm Power 9V Battery x 2 LCD Display 4 x 16 Character Valid visual field 61 6 x 25 2mm Test...

Страница 6: ...ble Error Check errors such as open circuit short circuit reverse connection or crossover Auto Time Delay Shut Off 30 minutes of inactivity Test Result 1 Short Circuit SHORT If any short circuit is fo...

Страница 7: ...unctions 1 Wiremap Wiring diagram measurement to check end to end continuity of cables in M L R and locate errors 2 Pair Length Pair and measure length for open short points verify cable length open c...