background image

12

350A4502P760

 

TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when 

the control is not set on high, or if ventilation seems 

inadequate, check the following:

 Knockouts not removed from hood .

 Damper blade not opening .

 Reduced airflow because the duct is too small or the 

duct length is too long .

 The duct is blocked .

 Undersized or restrictive wall or roof cap .

 

REPLACE WIRING COVER

 

Replace the wiring cover .

 

CONNECT WIRING

 

Connect house black to hood black wire, house white 

to hood white wire, and house ground to hood green/

yellow wire . Securely tighten the strain relief clamp 

onto the house wiring .

19

20

17

 

CONNECT DUCTWORK TO HOOD

 

Use duct tape to make joints secure and air tight .

Note: 

Illustration shows rectangular to round duct adapter . 

Duct tape

16

 

REPLACE FILTERS

 

The installation is complete . Turn on power at service 

panel, and test for proper operation .

Installation Instructions

21

WARNING:

Hg

 - Lamp contains Mercury.  Manage in accord with 

disposal laws. 

See 

www.lamprecycle.org

 or 1-800-435-4448 .

For installation, handling and disposal precautions, refer to 

the fluorescent lamp packaging literature .

WARNING:

n

 To reduce the risk of electric shock, do not connect electrical 

power to the hood without both lamps in place.

CAUTION: 

n

 Do not touch the hood lamps when they are on. They may 

be hot enough to cause injury.

n

 To prevent injury from broken lamps, handle lamps 

carefully and do not operate hood without lamp lens covers 

in place.

This hood requires two Compact Fluorescent Lamps (CFL) 

with a GU24 base (included), maximum 15 watts .

To change the lamps:

 When installing or replacing a lamp, make sure that 

power to the light has been turned off . Never allow a 

lamp to come into contact with water .

 Remove the lens cover by sliding it in a horizontal direction 

and pulling it down and away from the hood .

 Grasp the lamp by the plastic base portion of the lamp 

and unscrew it .

 Replace with energy saving GE 15W Compact Fluorescent 

Lamp with GU24 base GE Service Part:  WB08X10064.

INSTALL LAMPS

 

 FOLLOW ELECTRICAL CODE

 

Complete the electrical wiring according to National 

Electrical Code and local codes .

 

NOTE:

 This hood must be permanently grounded .

 Connect 

house wiring

 (120 VAC) to hood wiring .

18

1" = 2 .5 cm; 1' = 0 .3 m

Содержание JVE330

Страница 1: ... Stainless Steel Surfaces 4 Vent Controls 3 Installation Instructions 5 12 Troubleshooting Tips 14 Consumer Support Consumer Support 18 Product Registration 15 Warranty 17 JVE330 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________ Serial __________________ Find these numbers on a label on the back wall of the hood Printed in China ...

Страница 2: ...E THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking on high heat or when flambéing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé C Clean ventilating fans frequently Grease should not be allowed to acc...

Страница 3: ...his reason the filters must ALWAYS be in place when the hood is used The grease filters should be cleaned once a month or as needed To remove press the filter locks back and pull the filters down and out To replace insert the rear filter tabs in the frame slots at the back of the opening Push the filters up and lock them into place To clean the grease filters soak them and then swish them around i...

Страница 4: ...y sliding it in a horizontal direction and pulling it down and away from the hood Grasp the lamp by the plastic base portion of the lamp and unscrew it Replace with energy saving GE 15W Compact Fluorescent Lamp with GU24 base GE Service Part WB08X10064 Hood Lights NOTE Charcoal filters are not included with the hood They must be ordered from your GEsupplier If the model is not vented to the outsid...

Страница 5: ...transition adaptor must be used Do not use less than a 7 diameter duct Maximum duct length For satisfactory air m ovement the total duct length of a 31 4 x 10 rectangular should not exceed 65 equivalent feet NOTE It s important that ducting be installed using the most direct route and with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure da...

Страница 6: ...w of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE When applicable install any makeup replacement air system in accordance with local build...

Страница 7: ...s for installation over ranges up to 30 wide If you are going to vent your range hood to the outside see the Ducting Requirements section for exhaust duct preparation 66 or more from the floor to the top of the hood 30 30 min Bottom edge of cabinet needs to be 30 or more from the cooking surface Flat blade and Phillips screwdrivers Pencil Metal snips in some applications Electric drill Saw saber o...

Страница 8: ...ON Determine the vent option that your installation will require from the following choices The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use IMPORTANT If the hood is to be installed in a recirculating non vented ductless manner do not knock out any vent openings in the hood Only an electrical access hole will be knocked out of the ...

Страница 9: ...nstructions REMOVE DUCT KNOCKOUT S If recirculating non vented ductless see note below and skip to Step 7 and proceed Using a flat blade screwdriver remove the appropriate duct knockout s from the top or back of the hood 31 4 x 10 Rectangular vertical discharge Remove top rectangular duct knockout only 31 4 x 10 Rectangular horizontal discharge Remove rear rectangular duct knockout only NOTE If th...

Страница 10: ...the locations on the cabinet for ductwork electrical wiring and keyhole screw slots C Recirculating non vented ductless Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots Since the hood is to be recirculated not to be vented outside do not cut out any vent openings in the wall or cabinet bottom FOR 31 4 x 10 RECTANGLE DUCTED DISCHARGE...

Страница 11: ...allation is complete 11 SCREW IN PARTWAY Drive a mounting screw from the hardware packet partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom 13 FEED IN WIRES Lift the hood into position and feed the house wiring through the wiring knockout 14 SECURE HOOD Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the nar...

Страница 12: ...800 435 4448 For installation handling and disposal precautions refer to the fluorescent lamp packaging literature WARNING n To reduce the risk of electric shock do not connect electrical power to the hood without both lamps in place CAUTION Do not touch the hood lamps when they are on They may be hot enough to cause injury To prevent injury from broken lamps handle lamps carefully and do not oper...

Страница 13: ...350A4502P760 13 Notes ...

Страница 14: ...The motor is probably Replace the filter if it is soiled If it is not soiled off and on overheating and turning itself or if replacing the filter does not solve the problem off This can be harmful to call for service the motor Filter may be excessively soiled Compact Fluorescent This is normal for Compact Allow lamp to run for several minutes If this warm up Lamp appears dim Fluorescent Lamps espe...

Страница 15: ...15 OWNERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR RÉSIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et envoyez à ...

Страница 16: ...STREET NO NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND RÉG TELEPHONE TÉLÉPHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL YES OUI NO NON IF YES SI OUI EXPIRATION Y A M D J NAME OF SELLING DEALER NOM DU MARCHAND INSTALLATIONDATE DATED INSTALLATION Y A M D J CORRESPONDENCE ENGLISH CORRESPON...

Страница 17: ...roduct is located in an area where service by a Mabe Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized Mabe Service Location for service Some provinces do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other right...

Страница 18: ...rder by phone at 800 661 1616 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us GEAppliances ca If you are not satisfied with the service you receive from GE contact us on o...

Отзывы: