background image

350A4502P760

11

 

CHOOSE VENTING OPTION 

8

The hood can be set to vent outside or to recirculate air 

back into the kitchen .

  

To vent to the outside,

 refer to steps 5 and 6.

  

To recirculate air into the kitchen, 

remove two 

screws securing the duct block off plate . Discard 

plate .  Replace two screws .

Note:  

Hood is E

nergy

 S

tar

®

 certified only when it vents 

air to the outside.

Installation Instructions

 

CUT HOLES

 

Cut holes at marked locations for duct and electrical 

wiring . For the vertical duct, cut out 3/4

 extra toward 

the front of the cabinet so you can move the duct 

freely when installing the hood . It may also ease 

installation by cutting the hole 10

1

2

 instead of 10

 .

 

FOR RECESSED-BOTTOM CABINETS 

ONLY

10

9

Wood shims

• If the cabinets have front, side or back trim, make 

 

2 wood shims the width of the trim and attach them to 

the cabinet bottom recess on both sides . See Step 7 for 

marking locations .

 

RUN WIRES

 

Run the electrical wires through the wall or cabinet 

according to National Electrical Code and applicable 

local codes .

 

NOTE:

 DO NOT turn the power on until installation is 

complete .

11

 

SCREW IN PARTWAY

 

Drive a mounting screw (from the hardware packet) 

partway into each center of the narrow neck of the 

keyhole slots marked on the cabinet bottom .

13

 

FEED IN WIRES

 

Lift the hood into position and feed the house 

wiring through the wiring knockout .

14

 

SECURE HOOD

 

Slide the hood back against the wall . Tighten the 

mounting screws . Be sure the screw heads are in 

the narrow neck of the keyhole slot .

Keyhole (4)

15

 

OPTIONAL POWER CORD KIT JXHC1

 

Use only with range hood cord-connection kits 

that have been investigated and found acceptable 

for use with this model range hood .

 

For installation with a standard 3-prong, grounded 

wall outlet, Power Cord Connection Kit model 

JXHC1 must be used . This kit contains a power 

cord and the hardware required to connect it 

to the range hood . It is available at extra cost 

from your GE supplier . Follow the Installation 

Instructions packed with the kit .

12

 

NOTE: 

If using optional Power Cord Kit JXHC1, feed 

the power cord through the hole in the top cabinet 

while raising the hood . Loop any excess length of 

cord and tie away with a suitable tape or tie .

Cabinet

7

3

4

″ 

 

3-prong  

wall outlet  

(if using cord 

connection)

1

1

4

″ 

 

1

3

4

″ 

dia . clearance hole  

for optional power 

supply location

CL

1" = 2 .5 cm; 1' = 0 .3 m

Содержание JVE330

Страница 1: ... Stainless Steel Surfaces 4 Vent Controls 3 Installation Instructions 5 12 Troubleshooting Tips 14 Consumer Support Consumer Support 18 Product Registration 15 Warranty 17 JVE330 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________ Serial __________________ Find these numbers on a label on the back wall of the hood Printed in China ...

Страница 2: ...E THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking on high heat or when flambéing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé C Clean ventilating fans frequently Grease should not be allowed to acc...

Страница 3: ...his reason the filters must ALWAYS be in place when the hood is used The grease filters should be cleaned once a month or as needed To remove press the filter locks back and pull the filters down and out To replace insert the rear filter tabs in the frame slots at the back of the opening Push the filters up and lock them into place To clean the grease filters soak them and then swish them around i...

Страница 4: ...y sliding it in a horizontal direction and pulling it down and away from the hood Grasp the lamp by the plastic base portion of the lamp and unscrew it Replace with energy saving GE 15W Compact Fluorescent Lamp with GU24 base GE Service Part WB08X10064 Hood Lights NOTE Charcoal filters are not included with the hood They must be ordered from your GEsupplier If the model is not vented to the outsid...

Страница 5: ...transition adaptor must be used Do not use less than a 7 diameter duct Maximum duct length For satisfactory air m ovement the total duct length of a 31 4 x 10 rectangular should not exceed 65 equivalent feet NOTE It s important that ducting be installed using the most direct route and with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure da...

Страница 6: ...w of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE When applicable install any makeup replacement air system in accordance with local build...

Страница 7: ...s for installation over ranges up to 30 wide If you are going to vent your range hood to the outside see the Ducting Requirements section for exhaust duct preparation 66 or more from the floor to the top of the hood 30 30 min Bottom edge of cabinet needs to be 30 or more from the cooking surface Flat blade and Phillips screwdrivers Pencil Metal snips in some applications Electric drill Saw saber o...

Страница 8: ...ON Determine the vent option that your installation will require from the following choices The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use IMPORTANT If the hood is to be installed in a recirculating non vented ductless manner do not knock out any vent openings in the hood Only an electrical access hole will be knocked out of the ...

Страница 9: ...nstructions REMOVE DUCT KNOCKOUT S If recirculating non vented ductless see note below and skip to Step 7 and proceed Using a flat blade screwdriver remove the appropriate duct knockout s from the top or back of the hood 31 4 x 10 Rectangular vertical discharge Remove top rectangular duct knockout only 31 4 x 10 Rectangular horizontal discharge Remove rear rectangular duct knockout only NOTE If th...

Страница 10: ...the locations on the cabinet for ductwork electrical wiring and keyhole screw slots C Recirculating non vented ductless Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots Since the hood is to be recirculated not to be vented outside do not cut out any vent openings in the wall or cabinet bottom FOR 31 4 x 10 RECTANGLE DUCTED DISCHARGE...

Страница 11: ...allation is complete 11 SCREW IN PARTWAY Drive a mounting screw from the hardware packet partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom 13 FEED IN WIRES Lift the hood into position and feed the house wiring through the wiring knockout 14 SECURE HOOD Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the nar...

Страница 12: ...800 435 4448 For installation handling and disposal precautions refer to the fluorescent lamp packaging literature WARNING n To reduce the risk of electric shock do not connect electrical power to the hood without both lamps in place CAUTION Do not touch the hood lamps when they are on They may be hot enough to cause injury To prevent injury from broken lamps handle lamps carefully and do not oper...

Страница 13: ...350A4502P760 13 Notes ...

Страница 14: ...The motor is probably Replace the filter if it is soiled If it is not soiled off and on overheating and turning itself or if replacing the filter does not solve the problem off This can be harmful to call for service the motor Filter may be excessively soiled Compact Fluorescent This is normal for Compact Allow lamp to run for several minutes If this warm up Lamp appears dim Fluorescent Lamps espe...

Страница 15: ...15 OWNERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR RÉSIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et envoyez à ...

Страница 16: ...STREET NO NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND RÉG TELEPHONE TÉLÉPHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL YES OUI NO NON IF YES SI OUI EXPIRATION Y A M D J NAME OF SELLING DEALER NOM DU MARCHAND INSTALLATIONDATE DATED INSTALLATION Y A M D J CORRESPONDENCE ENGLISH CORRESPON...

Страница 17: ...roduct is located in an area where service by a Mabe Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized Mabe Service Location for service Some provinces do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other right...

Страница 18: ...rder by phone at 800 661 1616 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us GEAppliances ca If you are not satisfied with the service you receive from GE contact us on o...

Отзывы: