CAUTION: 

Certain plumbing skills are needed for installation. If you are unsure about any part of the

installation of this product, consult a professional plumber.

Important Installation Recommendations

Read entire manual. Failure to follow all guidelines
and rules could cause personal injury or property
damage.

Before you begin installation, read these
Installation Instructions completely. Then, 
obtain all the materials and tools you will need 
to make the installation. Failure to properly 
install the softener voids the warranty.

Check local codes. The installation must conform 
to them.

In the Commonwealth of Massachusetts, Plumbing
Code 248 CMR shall be adhered to. Consult with 
your licensed plumber.

Use only lead-free solder and flux for all sweat-
solder connections, as required by state and
federal codes.

Connect the softener to the main water supply
pipe 

before

or 

ahead of the 

water heater. 

DO NOT

RUN HOT WATER THROUGH THE SOFTENER.

Temperature of water passing through the
softener must be less than 120°F.

Use care when handling the softener. Do not 
turn upside down, drop, drag or set on sharp
protrusions.

Maximum allowable inlet water pressure is 125 psi.
If daytime pressure is over 80 psi, nighttime
pressure may exceed the maximum. Use a
pressure reducing valve if necessary. (Adding a
pressure reducing valve may reduce the flow.)

The softener works on 24 volt-60 Hz electrical
power only. Be sure to use the included
transformer. Be sure the electric outlet and
transformer are in an inside location to protect
from wet weather.

See 

Where to Install the Softener 

section for 

more details.

WARNING: 

Do not use with water that 

is microbiologically unsafe or of unknown quality 
without adequate disinfection before or after the
system. The water should be tested periodically to
verify that the system is performing satisfactorily. 

Small parts remaining after the installation could
be a choke hazard. Discard safely.

Unpacking and Inspection

Be sure to check the entire softener for any
shipping damage or parts loss. Also note damage 
to the shipping cartons. Contact the transportation
company for all damage and loss claims. The
manufacturer is not responsible for damages 
in transit.

Small parts, needed to install the softener, are on 
a skin-packed cardboard piece. To avoid loss of the 
small parts, keep them on the skin-pack until you
are ready to use them.

Содержание GNSF35Z

Страница 1: ...ep by Step Instructions 6 11 Tools and Materials Required 4 Unpacking and Inspection 3 Operating Instructions Tips Breaking a Salt Bridge 13 Cleaning Nozzle and Venturi Assembly 13 Features 14 Service 12 Water Softener System 12 17 Care and Cleaning 18 Troubleshooting Tips 19 21 Consumer Support Consumer Support Back Cover Parts List Catalog 22 25 Product Registration 29 30 Warranty 31 Owner s Man...

Страница 2: ...atures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 100 F Do not install in direct sunlight Excessive sun heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances Use only lead free solder and flux for all sweat solder connections as required b...

Страница 3: ...side down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime pressure may exceed the maximum Use a pressure reducing valve if necessary Adding a pressure reducing valve may reduce the flow The softener works on 24 volt 60 Hz electrical power only Be sure to use the included transformer Be sure the electric outlet and...

Страница 4: ...n and out fittings included with the softener are 3 4 nominal copper sweat tubes You should maintain the same or larger pipe size as the water supply pipe up to the water softener inlet and outlet Use the included bypass valve to install the softener The bypass valve allows you to turn off water to the softener for servicing but still have water in the house pipes The in and out fittings referred ...

Страница 5: ...olt outlet MAIN WATER PIPE Soft water Hard water Copper tube 3 4 2 Washer 2 Installation adapter 2 see above INLET NOTE Threads on the installation adapters are 1 male pipe If 1 pipes are needed do not use the copper tubes and nuts included Buy 1 pipe thread female adapter and plumb directly to 1 threads on installation adapters 24V transformer 120 volt outlet Bypass valve Hard water to outside fa...

Страница 6: ...ed to attach to the valve drain fitting Fig 4A To keep water pressure from blowing the hose off use a hose clamp to secure in place Locate the other end of the hose at a suitable drain point floor drain sump laundry tub etc that terminates at the sewer Check and comply with local codes IMPORTANT If more drain hose is needed it should be ordered from GE Parts at 800 626 2002 The water softener will...

Страница 7: ... Place bypass valve in bypass position by pushing the stem inward 7 6 5 4a Fig 4B Fig 5 Overflow drain hose Hose clamp Grommet Clip 1 4 NPT threads Barbs 1 2 O D copper tube not furnished Cut barbs from drain fitting Compression fitting 1 4 NPT X 1 2 O D tube not furnished Do not connect to valve drain hose Fully open the house main water pipe shutoff valve Observe a steady flow from both faucets ...

Страница 8: ...es the hardness value UP increases the hardness value NOTE Each press of a button changes the display by 1 between 1 and 25 Above 25 the display changes 5 at a time 25 30 35 etc Holding a button in changes the numbers at a rapid rate 3 When the display shows your water hardness in grains per gallon press SELECT to accept NOTE If there is clear water iron in your water supply you will need to incre...

Страница 9: ...difference between these two cycles is highly dependent on the water usage and hardness at a particular installation NOTE California Regulations require this feature to be ON for installations in California To access the Salt Efficiency press and hold the SELECT button for 3 seconds The System Diagnostics display will appear Press the SELECT button again and the Salt Efficiency display will appear...

Страница 10: ...contaminate your water supply and will not cause bacteria to form or grow However during shipping storage installing and operating bacteria could get into the softener For this reason sanitizing as follows is suggested when installing NOTE Sanitizing is recommended by the Water Quality Association for disinfecting Be sure to complete all installation steps including timer programming Remove the br...

Страница 11: ... iron removal Refer to Cleaning Iron Out of the Water Softening System section Canada working pressure limits 1 4 7 0 kg cm2 GNSF35Z Rated capacity see rating label on water softener Rated efficiency see rating label on water softener Amount of high capacity resin lbs cu ft 48 9 94 Resin tank nominal size in dia x height 9 x 40 Service flow rate gpm see rating label on water softener Water supply ...

Страница 12: ...n beads To make the brine water flows into the salt storage area during the fill stage as shown Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard minerals from the resin beads The hard minerals and brine are discharged to the drain The nozzle and venturi create a suction to move the brine maintaining a very slow ra...

Страница 13: ...tighten the cap or housing IMPORTANT Be sure small holes in the gasket are centered directly over the small holes in the nozzle and venturi housing Install with numbered side up concave side down Cap O ring seal Screen support Screen Screen Nozzle Venturi Nozzle Venturi housing Gasket Fill Flow plug Breaking a Salt Bridge Sometimes a hard crust or salt bridge forms in the salt storage area It is u...

Страница 14: ...immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When power is restored you ha...

Страница 15: ...agnostics NO POWER POWER OK REPAIR AS NEEDED CONTROL DEFECTIVE Do manual diagnostics to verify proper function Electrical power was off Reset the correct time of day Investigate reason for power loss www GEAppliances com Service Electronic Demand Time Features and Service If you are not getting soft water and an error code is not displayed use the procedures below to find the problem First make th...

Страница 16: ... retained by the computer from the first time electrical power is applied to the control Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to display the number of regenerations initiated by this control since the SR code number was entered 2 Press the SELECT button and hold in three seconds until a Service Ratin...

Страница 17: ...the liquid level over an extended period of time NOTE Be sure a salt bridge is not preventing water from contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective nozzle and venturi not seated properly on gasket restricted drain check drain fitting and hose defective nozzle and ventur...

Страница 18: ...em takes hardness minerals calcium and magnesium out of the water Also it can control some see Specification Guidelines section clear water iron With clear water iron water from a faucet is clear when first put into a glass After 15 to 30 minutes the water begins to cloud or turn rust colored A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from th...

Страница 19: ...to electrical display and read Program Memory section outlet Electrical outlet on a circuit that NOTE The electrical outlet for the softener should be continuously can be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass Be sure the bypass valve stem is positioned properly with the position knob in the OUT position Observe instructions on the decal at the en...

Страница 20: ... color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Service Manually Inititated Electronic Diagnostics not regenerating section for troubleshooting procedures page 16 Call for service Sensor wire corroded See the Service Manually Inititated Electronic Diagnostics section for troubleshooti...

Страница 21: ... has air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose Unplug transformer in control Remove control cover release clips on side Check for loose incorrect wiring connections to electronic board or switch Reconnect as required Reassemble control cover Plug in transformer Wait six minutes for error code...

Страница 22: ...22 Parts list Model GNSF35Z03 ...

Страница 23: ...23 Parts list www GEAppliances com ...

Страница 24: ... 1 0019 WS33X10002 RIM 1 0020 WS31X10003 COVER BRINEWELL 1 0021 WS02X10009 WING NUT 1 4 20 1 0022 WS32X10002 TANK BRINEWELL ROUND 1 0023 WS02X10011 SCREW 1 4 20 NYLON 1 0024 WS32X10003 TANK BRINE ROUND 1 0025 WS18X10003 CLAMP HOSE 1 0026 WS22X10016 ADAPTER HOSE 1 0027 WS22X10017 GROMMET 1 0028 WS35X10035 GROUND CLAMP KIT 1 0029 WS15X10005 BRINE VALVE ASM 1 0030 WS35X10003 FLOAT STEM GUIDE ASM 1 00...

Страница 25: ...T 1 0115 WS03X10015 CONE SCREEN 1 0116 WS22X10021 PLUG FILL FLOW 3 GPM 1 0117 WS03X10017 NUT FERRULE 1 0118 WS15X10009 NOZZLE VENTURI ASM 1 0119 WS03X10018 RETAINER 1 0120 WS03X10019 SEAL O RING 1 4 X 3 8 2 0121 WS15X10010 BODY VALVE 1 0122 WS03X10020 SPRING 1 0123 WS22X10022 PLUG DRAIN SALT 1 0130 WS35X10005 SEAL KIT 1 0132 WS22X10023 ADAPTER DRAIN HOSE 1 0133 WS03X10021 O RING 5 8 X 13 16 1 0134...

Страница 26: ...26 Notes ...

Страница 27: ...27 Notes ...

Страница 28: ...28 Notes ...

Страница 29: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Страница 30: ...the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual carefully It will help you operate your new appliance properly Model Number Serial Number E ma...

Страница 31: ...ters membranes or batteries Replacement of house fuses or resetting of circuit breakers Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this appliance Damage caused after delivery This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA In Al...

Страница 32: ...extended warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sen...

Отзывы: