33
Maintenance
Maintenance
Maintenance
Cleaning the Valve
CAUTION
Cleaning agents spraying out due to excess pressure in the container to be
cleaned
If the container to be cleaned is under excess pressure, the pressure is released into the
atmosphere during lifting. If this happens during cleaning, when cleaning solution is
continuously sprayed into the valve housing, the air flowing out carries the cleaning solu-
tion along. This liquid can spray out of the collecting pan for the vacuum pan. Depending
on the level of the excess pressure, a considerable amount of cleaning solution can
emerge. These effects are physical and cannot be avoided.
Use the lifting function only when the container is not under pressure.
Lift the pressure relief valve disk before lifting the vacuum valve disk, in order to
reduce spraying if a residual overpressure exists.
Use the lifting function only when the collecting pan for the vacuum valve is empty.
IMPORTANT NOTE
Valve disk, housing seat and valve seat are precision parts.
Damage to these parts can result in malfunctions.
Handle the valve with care!
IMPORTANT NOTE
Damage to the valve
Damage to the valve can result in a malfunction.
Observe the safety information sheets issued by the detergent manufacturers!
Only use detergents which are non-abrasive and not aggressive towards stainless
steel.
Carry out the following steps:
1.
Disassemble the valve, see “Disassembling the Valve“ (Page 30).
2.
Carefully clean the individual parts.
Done
Содержание VARIVENT Vacuum Valve V
Страница 1: ...Operating Instructions VARIVENT Vacuum Valve V Edition 2016 06 30 English...