2
Safety
2.1
Intended use
The VARIVENT
®
FRS valve is designed for use with powdery media as well as
CIP and drying processes. The powder medium is conveyed through the process
housing with the valve closed. By means of flush bores, preferably sterile
compressed air that flows through a gap in the valve disk to the process housing,
can be applied to the valve seat. Thanks to this pressurisation any collection of
powder at the valve seat can be avoided.
When the valve is open, cleaning medium can be fed via the single-spout CIP
housing. After the CIP cleaning has been carried out, the valve can be dried in
open valve position with hot air or steam (see “Technical data” (page 21).
The FRS valve is used for opening and closing pipeline sections.
Hint!
The manufacturer will not accept any liability for damage resulting
from any use of the valve which is not in accordance with the
designated use of the valve. The risk of such misuse lies entirely with
the operator of the facility.
2.1.1
Requirements for operation
The prerequisite for reliable and safe operation of the component is proper
transportation and storage as well as professional installation and assembly.
Operating the unit within the limits of its designated use also involves adhering to
the operating, inspection and maintenance instructions.
2.1.2
Pressure equipment directive
The component is a piece of pressure equipment (without safety function) in the
sense of the pressure equipment directive 2014/68/EU. Classified according to
Annex II in category 1.
According to the scope of directive 2014/34/EC, article 1, paragraph 2, f, the
exception of the directive applies, due to conformity with the machine directive
2006/42/EU.
The nominal diameters smaller than DN 25 are subject to article 4, paragraph 3
of the Pressure Equipment Directive which specifies sound engineering practice.
Nominal diameters ≥ IPS 4“; DN 125 valid for the fluid group II.
In the event of any deviations, GEA Tuchenhagen GmbH will supply a specific
Declaration of Conformity.
2.1.3
ATEX directive
In areas with an explosive atmosphere, only valves suitable for use in such areas
may be used.
Please observe chapter 7.3 “Use of the valve in potentially explosive
atmospheres”.
Safety