Installing ADAPTA bearing support size 3
Connect the bearing carrier (0330.00) and motor
(0801.00) with the spring washers (0934.06) and
hex nuts (0920.09).
Fig.57:
Bearing support
Align the coupling half (0840.01). Permissible axial
offset of the coupling halves: 4 mm (0.16")
Fig.58:
Axial offset
Fasten the coupling half (0840.01) with the set
screw (0904.00)
Torque M8: 6 ft lb (8 Nm)
Fig.59
→ The ADAPTA bearing support has been installed.
Malfunctions / repairs
Repair
BA.H2A.ADY.002.GB_1
68
18.12.2017