 Dimensions and connections

Dimensions in mm

Fig. 28

1)

 SV 90° rotatable

Dimensions in ( ) = HGX34P/315-2 S A K
 

         HGX34P/380-2 A K

 HGX34P aluminium 2-pole K 

 

HGX34P/315-2 A K 

HGX34P/380-2 A K

 

 

 

 

HGX34P/315-2 S A K 

*) 

about 300 mm at terminal box in   

   lower dimension (Accessories)

Centre of gravity

310

420

46 (43)

ca.515 (510)

79 (74)

ca.135

ca.170

273 

(271)

230

ca.285

ca.340

419 (452)

ca.170(185)

ca.

135

SV

A1

A1

O,K

B1

DV

A

H,D1

F

J

E

B,L

272

ca.315

4x 12

115

Teile Nr.

14371

HGX34P/215-4 S

Typ

14041

14358

HGX34P/380-4

HGX34P/315-2

HG34P/215-4 S

14375

HG34P/255-4

14359

14356

HGX34P/255-4

Typ

14360

HG34P/255-4 S

HGX34P/380-2

14372

Teile Nr.

HGX34P/255-4 S

14042

HGX34P/255-2

Typ

14374

14378

Typ

HGX34P/380-4 S

14043

14376

Teile Nr.

HG34P/315-4

HGX34P/315-2 S

14357

HGX34P/315-4

14361

HG34P/315-4 S

14040

14373

HGX34P/315-4 S

HG34P/380-4 S

14377

HG34P/380-4

14362

Teile Nr.

HG34P/215-4

14355

HGX34P/215-4

Anschlüsse

Connections

Raccords

HG34P/215-4 HG34P/255-4 HG34P/380-4 

HG34P/315-4

HGX34P

2-Pol

SV Saugabsperrventil, Rohr   (L)*

Suction line valve, tube   (L)*

Vanne d’arrêt  d’aspiration,   de tuyau (L)*

mm - Zoll

22 – 7/8"

28 – 1 1/8"

28 – 1 1/8"

35 - 1 3/8" 

DV Druckabsperrventil, Rohr   (L)*

Discharge line valve, tube   (L)*

Vanne d’arrêt de refoulement,   de tuyau (L)* mm - Zoll

16 - 5/8"

16 - 5/8"

22 – 7/8"

22 - 7/8"

A

Anschluß Saugseite, nicht absperrbar

Connection suction side, not lockable

Raccord côté aspiration, non obturable

Zoll

1/8" NPTF

A1 Anschluß Saugseite, absperrbar

Connection suction side, lockable

Raccord côté aspiration, obturable

Zoll

7/16" UNF

B

Anschluß Druckseite, nicht absperrbar

Connection discharge side, not lockable

Raccord côté refoulement, non obturable

Zoll

1/8" NPTF

B1 Anschluß Druckseite, absperrbar

Connection discharge side, lockable

Raccord côté refoulement, obturable

Zoll

7/16" UNF

D1 Anschluß Ölrückführung vom Ölabscheider Connection oil return from oil separator

Raccord retour d’huile du séparateur d’huile

Zoll

1/4" NPTF

E

Anschluß Öldruckmanometer

Connection oil pressure gauge

Raccord du manomètre de pression d’huile

Zoll

1/8" NPTF

F

Ölablaß

Oil drain

Vidange d’huile

mm

M10

H

Stopfen Ölfüllung

Oil charge plug

Bouchon de remplissage d’huile

Zoll

1/4"NPTF

J

Ölsumpfheizung

Oil sump heater

Chauffage du carter d’huile

mm

15

K

Schauglas

Sight glass

Voyant

Zoll

1 1/8" – 18 UNEF

L

Anschluß Wärmeschutzthermostat

Connection thermal protection thermostat

Raccord de thermostat de protection thermique

Zoll

1/8" NPTF

O

Anschluß Ölspiegelregulator

Connection oil level regulator

Raccord régulateur de niveau d’huile

Zoll

1 1/8" – 18 UNEF

(L)* = Lötanschluß

(L)* = Brazing connection

(L)* = Raccord à braser

Dimensions in (  ) for HG(X)34P/215-4 (S) and 255-4 (S)

Cotes en mm

Maße in mm

Änderungen vorbehalten

Dimensions in mm

Maße in (  ) für HG(X)34P/215-4 (S) und 255-4 (S)

Maße Zubehör / Dimensions Accessories / Dimensions Accessoires

Sous réserve de toutes modifications

Subject to change without notice

Cotes en (  ) pour HG(X)34P/215-4 (S) et 255-4 (S)

Halbhermetischer Verdichter HG / Semi-hermetic compressor HG / Compresseur semi-hermétique HG

Massenschwerpunkt

Centre of gravity

Centre de gravité

1.0850-14374.0 q

Rz 63

Rz 6,3

Maßstab:

%

F

E

D

C

B

A

F

E

D

C

CA

D-

Ze

ic

hnung

 - Da

rf 

nur

 ma

sc

hine

ll g

nde

rt 

w

er

de

n.

4

3

2

1

A

B

5

6

7

8

1

2

3

4

5

6,3

über 0.5

8

Zeichn.-Nr. / Drawing no. /

Numéro de plan:

Tol.-Ang. DIN ISO 2768-mK

1

R

ev

is

io

ns

dur

chl

auf

:

Betrifft Bl.2+3

Rz 160

Ra   Rz

s

25

2-Pol Ausführungen und Schwerpunkt ergänzt

Maß

Passung

Freigabe

Alternativbezug:
Baumustergeprüft

Teil inaktiv

Lieferantenzeichnung

-

-

K.-Auftrag:

PL:

Zeichnung ungültig

Entwicklungsstand

Teil keine Serie

120

400

±0.5

bis      6

Benzstraße 7    -    72636 Frickenhausen    -    Germany     -    www.bock.de

Layh
Layh

Schni

Schni

27.08.09
23.06.09

7562

7466,7519,7531,7539

-

Betrifft Bl.2-4
Betrifft Bl.3+4

q
p
o

-

Layh

Buck

16.10.08

7341,7375,7407

-

n

-

Unbemaßte Radien:

-

z

y

x

6

Rz 16

Rz 25

2

1,6

Rz 12,5

0,7

0,3

7

u

t

an dieser Zeichnung vor.

Bearb.

Datum

Änderungs-Nr.

Werkstoff:

Ausgangsteil, bzw. Rohteil:

-

-

Gepr.

Name

Datum

02.06.

01.07.

0,05 Rz 1,6

Werkstückkanten

DIN ISO 13715

Ersatz für:

Ersetzt durch:

Erstellt

2003

Geprüft

1.0850-14374.0 m

Söll

Bauknecht

Zone

1/4

Oberflächenbehandlung / Härte:

-

Blatt:

Änderungsbeschreibung

 400

Benennung:

±0.8

1000

 30

 6

-

±0.3

120

30

±0.2

Zeichn.-Nr.         Teile-Nr.

Oberflächenangaben

nach DIN ISO 1302

1.0850-14374.0

Zust.

Gußtoleranzen:

Gewicht: (kg)

±0.1

w

-

-

7601, 7624

18.11.09 Büttner

Layh

Diese      Zeichnung       ist        unser        Eigentum!

Sie   darf  ohne unsere  Genehmigung  weder  nach-

gebildet,   vervielfältigt,   oder  Dritten  Personen  zu-

gänglich   gemacht    werden.   Der   Nachbau   nach

dieser   Zeichnung,  oder  an  Hand  der  nach dieser

Zeichnung   hergestellten   Gegenstände  durch  den

Abnehmer oder Dritte ist nicht gestattet.

Wir behalten uns alle Rechte, gemäß DIN ISO 16016

HG34P/380-4 S

Schwingungsdämpfer

Vibration absorbers

Amortisseurs de vibration

30

40

10

M

20

ca.620

ca.350

ca.550

SV

Dimensions et raccords différées version à 2 pôles

Differing measures and connections 2-pole version

Abweichende Maße und Anschlüsse 2-Pol Ausführung

Maße in ( ) für HGX34P/315-2 S + 380-2

Cotes en ( ) pour HGX34P/315-2 S + 380-2

Dimensions in ( ) for HGX34P/315-2 S + 380-2

ca.540 (570)

A

A1

SV

Vibration
damper

SV
DV

Suction line
Discharge line                   see technical data, Chapter 8

A

Connection suction side, not lockable

1/8“ NPTF

A1

Connection suction side, lockable

7/16“ UNF

B

Connection discharge side, not lockable

1/8“ NPTF

B1

Connection discharge side, lockable 

7/16“ UNF

D1

Connection oil return from oil separator

1/4“ NPTF

E

Connection oil pressure gauge

1/8“ NPTF

F

Oil drain

M10

H

Oil charge plug

1/4“ NPTF

J

Connection 

oil sump heater

Ø 15 mm

K

Sight glass

1 1/8“-  18 UNEF

L

Connection thermal protection thermostat

1/8“ NPTF

O

Connection oil level regulator

1 1/8“-  18 UNEF

 ca.320*

Содержание HGX34P Series

Страница 1: ... world 1 2 3 4 5 6 7 8 9 10 11 12 13 GEA Compressor HGX34P 2 pole Assembly instructions HGX34P 255 2 HGX34P 315 2 S HGX34P 255 2 A HGX34P 315 2 S A HGX34P 380 2 HGX34P 315 2 HGX34P 315 2 A K HGX34P 380 2 A HGX34P 315 2 A HGX34P 315 2 S A K HGX34P 380 2 A K ...

Страница 2: ...compressor can result in serious or fatal injury Observe the safety instructions contained in these instructions These instructions must be passed onto the end customer along with the unit in which the compres sor is installed GEA Bock GmbH 72636 Frickenhausen GEA Bock GmbH Benzstraße 7 72636 Frickenhausen Germany Telephone 49 7022 9454 0 Fax 49 7022 9454 137 refrigeration gea com www gea com Manu...

Страница 3: ...rating mode of the lockable service connections discharge line valve 5 Electrical connection 15 5 1 Information for contactor and motor contactor selection 5 2 Connection of the driving motor star circuit 5 3 Connection of the driving motor part winding circuit 5 4 Circuit diagram 5 5 Electronic trigger MP 10 5 6 Connection of the electronic trigger MP 10 5 7 External connection MP10 5 8 Functiona...

Страница 4: ...ge INFO Important information or tips on simplifying work WARNING Inadequately qualified personnel poses the risk of accidents the consequence being serious or fatal injury Work on compressors is therefore reserved for personnel which is qualified to work on pressurized refrigerant systems For example a refrigeration technician refrigeration mechatronic engineer As well as professions with compara...

Страница 5: ...d in potentially explosive environments These assembly instructions describe the standard version of the compressor named in the title man ufactured by GEA GEA refrigerating compressors are intended for installation in a machine within the EU according to the EU Directives 2006 42 EC Machinery Directive 97 23 EC Pressure Equipment Directive Commissioning is permissible only if the compressor has b...

Страница 6: ...m design Suction gas cooled drive motor 2 Product description Fig 1 2 1 Short description Fig 2 Oil sight glass Valve plate Cylinder cover Discharge line valve Oil pump Terminal box Suction line valve Drive section Motor section Dimension and connection values can be found in Chapter 9 Transport eyelet Name plate 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Страница 7: ...GX34P 380 2 A 38 0 Y 172 A 380 420V Y 3 50HZ 440 480V Y 3 60HZ 2900 3480 AS38125A001 Fig 3 1 Type designation 6 Voltage circuit frequency 2 Machine number 7 Nominal rotation speed 3 maximum operating current 8 Displacement 4 Starting current rotor blocked 9 Voltage circuit frequency 5 ND LP max permissible operating 10 Nominal rotation speed pressure g Low pressure side 11 Displacement HD HP max p...

Страница 8: ...ulator is activated is not permissible and can cause damage to the compressor The suction gas superheat temperature may need to be reduced or set individually when operating near to the threshold When the capacity regulator is activated the gas velocity in the system can not under certain circumstances ensure that suffici ent oil is transported back to the compressor For operation with frequency c...

Страница 9: ...ably for R407C Evaporating temperature C Condensing temperature C Suction gas temperature C R134a 50 Hz R407C 50 Hz Unrestricted application range 1 HGX34P 380 2 A observe the operating limits Evaporating temperature C Condensing temperature C Suction gas temperature C Max permissible operating pressure LP HP 1 19 28 bar 1 LP Low pressure HP High pressure ...

Страница 10: ... K observe the operating limits Design for other ranges on request Unrestricted application range Evaporating temperature C Condensing temperature C Suction gas temperature C Unrestricted application range Evaporating temperature C Condensing temperature C Suction gas temperature C Max permissible operating pressure LP HP 1 19 28 bar 1 LP Low pressure HP High pressure ...

Страница 11: ... Benennung Zeichn Nr Teile Nr x xxxx xxxxx x Maßstab 1 1 4 3 Maximum permissible inclination A a A a a A a A Fig 14 INFO New compressors are factory filled with inert gas 3 bar nitrogen Leave this service charge in the compressor for as long as possible and prevent the ingress of air Check the compressor for transport damage before starting any work ATTENTION Poor lubrication can damage the compre...

Страница 12: ...t being a loss of refrigerant INFO Proper layout of the suction and discharge lines directly after the compressor is integral to the system s smooth running and vibration behaviour Rigid fixed point As short as possible Fig 16 ATTENTION Damage possible Do not solder as long as the compressor is under pressure Superheating can damage the valve Remove the pipe supports therefore from the valve for s...

Страница 13: ...eft counter clockwise as far as it will go Shut off valve completely opened service connection closed The connection which cannot be shut off is intended for safety devices Fig 20 Opening the service connection Spindle Turn 1 turn clockwise Service connection opened shut off valve opened The connection which cannot be shut off is intended for safety devices Service connec tion closed Connection bl...

Страница 14: ...ff valve completely opened service connection closed Fig 22 Opening the service connection Spindle Turn 1 turn to the right clockwise Service connection opened shut off valve opened Service connec tion closed Connection blocked Spindle Service connec tion opened Spindle Connection open Compressor Compressor After activating the spindle generally fit the spindle protection cap again and tighten wit...

Страница 15: ...e which must respond at 1 2 times the set current within 2 hours and must not have responded at 1 05 times the set current within 2 hours or another comparable device INFO Connect the compressor motor in accordance with the circuit diagram see inside of terminal box Use suitable cable entry point of the correct protection type see name plate for routing cables into the terminal box Insert the stra...

Страница 16: ...the terminal box Y Star delta start up is only possible on 230 V voltage supply Example 400 V Y Direct start only Elektrischer Anschluss Electrical connection Raccordement électrique Y 96027 11 06 DGbF Niedere Spannung Low voltage Bas voltage Y Hohe Spannung High voltage Haut voltage L3 L1 L2 L3 L1 L2 Y 5 Electrical connection ...

Страница 17: ...es Klemmen kastens siehe Abbildung Verdichter mit dieser Kennzeichnung sind im Spannungsbereich für Stern Dreieck Anlauf geeignet Der Anschluss im Klemmenkasten ist werkseitig für Direktstart Y vorgesehen Direktstart Beispiel für Motor 230 V 400 V Y Klemmbrett mit eingelegten Brücken für den Direktstart a bei niederer Spannung b bei höherer Spannung 230 V 3 400 V Y 3 Abb schematisch Y YY PW ATTENT...

Страница 18: ...Fig 23 Compressor terminal box R1 Cold conductor PTC sensor motor winding R2 Thermal protection thermostat PTC sensor F1 Load circuit safety switches F2 Control power circuit fuse F3 Safety chain high low pressure monitoring B1 Release switch thermostat pressostat Q1 Main switch ...

Страница 19: ...K1 Compressor contactor MP10 Electronic trigger unit MP 10 E Oil sump heater X3 Terminal strip in terminal box XSS Terminal strip in the external switch cabinet A1 Alarm Motor protection A2 Overheating R1 R2 A3 Alarm high pressure XSS Terminal strip in the external switch cabinet ...

Страница 20: ...g F von max 4 A träge abzusichern Um die Schut funktion zu gewährleisten ist das Auslösegerät als erstes Glied in den Steuerstrom kreis zu installieren Anschlüsse Temperaturüberwachung Motorwicklung Klemmen 1 2 Heißgasseite Klemmen 3 4 Klemmen 1 6 am Auslösegerät MP 10 und Klemmen PTC 1 und PTC 2 am Verdichterklemmbrett dürfen nicht mit Netzspannung in Berührung komme Das Auslösegerät und die PTC ...

Страница 21: ...upply L1 or S1 OFF OFF OFF Release the motor temperature sensor connection 1 or 2 Release the hot gas temperature sensor if installed 3 or 4 2 Restore the power supply L1 or S1 ON Function check of motor temperature sensor operational ON Function check of hot gas temperature sensor operational ON 3 Interrupt power supply again L1 or S1 OFF OFF OFF Reconnect terminals 1 or 2 and or 3 or 4 4 Restore...

Страница 22: ...test purposes must only be operated with refrigerant Under vacuum the spark over and creepage current distances of the terminal board connection bolts shorten this can result in winding and terminal board damage 6 3 Leak test Carry out the leak test on the refrigerating plant in accordance with EN 378 2 or a corresponding safety standard while always observing the maximum permissible overpressure ...

Страница 23: ...tem must be properly designed All components must be compatibly rated with each other with regard to output particularly the evaporator and expansion valves Suction gas superheat at the compressor input should be min 7 10 K check the setting of the expansion valve The system must reach a state of equilibrium Particularly in critical systems e g several evaporator points measures are recommended su...

Страница 24: ...l change is not mandatory if the system is correctly manufactured and operated However based on decades of experience we recommend that the following oil change service work is carried out First oil change during the first maintenance of the system Then after every 10 000 12 000 operating hours though no more than 3 years clean the oil strainer at the same time Dispose of the oil inside in accorda...

Страница 25: ...eniso Triton SEZ 32 Esso Mobil EAL Arctic 46 Sunoco Suniso SL 46 Texaco Capella HFC 55 7 6 Decommissioning Close the shut off valves on the compressor Drain the refrigerant it must not be discharged into the environment and dispose of it according to the regulations When the compressor is depressurised undo the fastening screws of the shut off valves Remove the compressor using an appropriate hois...

Страница 26: ... 5 172 67 67 64 5 64 1 2 3 2 4 380 420 V Y 3 50 Hz 5 L M H Oil charge Weight Tolerance 10 relative to the mean value of the voltage range Other voltages and types of current on request The specifications for max power consumption apply for 50Hz operation For 60Hz operation the specifications have to be multiplied by the factor 1 2 The max working current remains unchanged Take account of the max o...

Страница 27: ...elative to the mean value of the voltage range Other voltages and types of current on request The specifications for max power consumption apply for 50Hz operation For 60Hz operation the specifications have to be multiplied by the factor 1 2 The max working current remains unchanged Take account of the max operating current max power consumption for design of fuses supply lines and safety devices ...

Страница 28: ... K O B L B1 DV 115 ca 315 272 4x 12 ca 285 230 273 79 46 310 419 452 ca 135 ca 185 215 K O H D1 F E B1 A B L DV ca 285 115 ca 315 272 4x 12 A SV A1 1 SV J ca 540 570 Centre of gravity Centre of gravity 310 420 46 43 ca 515 510 79 74 ca 135 ca 170 273 271 230 ca 285 SV A1 A1 O K B1 DV A H D1 F J E B L 272 ca 315 4x 12 115 Cotes en mm Maße in mm Änderungen vorbehalten Dimensions in mm Maße in für HG...

Страница 29: ... vom Ölabscheider Connection oil return from oil separator Raccord retour d huile du séparateur d huile Zoll 1 4 NPTF E Anschluß Öldruckmanometer Connection oil pressure gauge Raccord du manomètre de pression d huile Zoll 1 8 NPTF F Ölablaß Oil drain Vidange d huile mm M10 H Stopfen Ölfüllung Oil charge plug Bouchon de remplissage d huile Zoll 1 4 NPTF J Ölsumpfheizung Oil sump heater Chauffage du...

Страница 30: ...rds referenced A partly completed machine may only be put into operation when it has been established that the machine into which the partly completed machine is to be installed conforms to the regulations of the Machinery Directive 2006 42 EC The manufacturer undertakes to transmit electronically the special documentation required by individual states for partly completed machinery on request The...

Страница 31: ...tions about installation operation and accessories please contact our technical service or specialist wholesaler and or our representative The GEA service team can be contacted by phone with a toll free hotline 00 800 800 000 88 or via e mail refrigeration gea com Yours faithfully GEA Bock GmbH Benzstraße 7 72636 Frickenhausen Germany 11 Service ...

Страница 32: ... 137 refrigeration gea com www gea com We live our values Excellence Passion Integrity Responsibility GEA versity GEA Group is a global engineering company with multi billion euro sales and operations in more than 50 countries Founded in 1881 the company is one of the largest providers of innovative equipment and process technology GEA Group is listed in the STOXX Europe 600 index ...

Отзывы: