Product description
Fig. 3
2.2 Name plate
(example)
1
2
3
4
5
13
12
7
11
6
10
8
9
27/43
AS33567A001
HGX22P/125-4 S R410A
19,2/11,1 A
121 A
70 A
Öl: SE 55
/
HG
2
2 P 125-4 S R410A
X
2.3
Type key
(example)
¹
)
HG - Hermetic Gas-cooled (suction gas-cooled) for normal and air conditioning applications
²
)
Additional declaration for Pluscom compressors
³
)
S - More powerful motor, e.g. air conditioning applications
R410A version
Motor variant ³
)
Number of poles
Swept volume
²
)
Number of cylinders
Size
Ester oil filling
Series ¹
)
IP66
1
Type designation
2
Machine number
3
maximum operating current
4
Starting current (rotor blocked)
5
ND (LP): max. admissible operating
pressure
(g)
Low pressure side
HD (HP): max. admissible operating
pressure
(g)
High pressure side
Observe the limits of
application diagrams!
50 Hz
60 Hz
6
Voltage, circuit, frequency
7
Nominal rotation speed
8
Displacement
9
Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12
Oil type filled at the factory
13 Terminal box protection type
Electrical accessories can change
the IP protection class!
}
}
GEA Bock GmbH
72636 Frickenhausen, Germany