Troubleshooting
Troubleshooting possible faults
2018-9015-001
09-2016
Electrical
Symptom
Possible cause
Solution
Signal lights / Halogen
lights do not turn on.
Electrical plug is not
connected to the tractor.
Connect electrical plug to
the tractor.
Light bulb burned out.
Replace light bulb.
Electrical wires cut.
Repair the electrical
problem.
Short circuit.
Options
Symptom
Possible cause
Solution
Recirculation system does
not recirculate.
Fibrous material can be
stuck in the recirculating
pipe.
Contact your dealer.
Anti-splash flapper door
stays open.
Dried manure located on
the door flap and/or on the
sides of the opening.
Clean door and/or sides
with water.
The suspension is not
efficient.
Defective hydraulic
cylinder.
Contact your dealer.
Not enough or too much
hydraulic oil in the cylinder.
Refer to section
Maintenance - Hydraulic
suspension.
The solenoid valve does
not work.
Electric wires are defective
or not connected.
Contact your dealer.
Self-loading option
Symptom
Possible cause
Solution
Hydraulic primer pump of
the self-loading kit does not
prime.
Suction hose is not well
positioned on the hose
support or is not air tight.
Reposition the suction
hose. Find air leak and
repair.
Foreign object in the check
valve or directional valve.
Contact your dealer.
Rubber seals are worn out.
Replace rubber seals.
Hydraulic reversing valve
pressure is not calibrated.
Refer to section
Maintenance - Primer pump
reversing valve.
The self-loading inner valve
cylinder is not in proper
position.
Refer to section Operating -
Operating spreader options
- Self-loading.
The gate valve beside the
latch mechanism is closed.
The ball valve on the latch
mechanism is open.
Note!
For any other faults, contact your dealer.